% SPDX-License-Identifier: Apache-2.0
|
||
|
||
# `POST /optimize` Optimization
|
||
|
||
## Introduction
|
||
|
||
The `POST /optimize` API endpoint optimizes your energy management system based on various inputs
|
||
including electricity prices, battery storage capacity, PV forecast, and temperature data.
|
||
|
||
The `POST /optimize` optimization interface is the "classical" interface developed by Andreas at the
|
||
start of the projects and used and described in his videos. It allows and requires to define all the
|
||
optimization paramters on the endpoint request.
|
||
|
||
:::{admonition} Warning
|
||
:class: warning
|
||
The `POST /optimize` endpoint interface does not regard configurations set for the parameters
|
||
passed to the request. You have to set the parameters even if given in the configuration.
|
||
:::
|
||
|
||
## Input Payload
|
||
|
||
### Sample Request
|
||
|
||
```json
|
||
{
|
||
"ems": {
|
||
"preis_euro_pro_wh_akku": 0.0001,
|
||
"einspeiseverguetung_euro_pro_wh": [
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007,
|
||
0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007
|
||
],
|
||
"gesamtlast": [
|
||
676.71, 876.19, 527.13, 468.88, 531.38, 517.95, 483.15, 472.28,
|
||
1011.68, 995.00, 1053.07, 1063.91, 1320.56, 1132.03, 1163.67,
|
||
1176.82, 1216.22, 1103.78, 1129.12, 1178.71, 1050.98, 988.56, 912.38,
|
||
704.61, 516.37, 868.05, 694.34, 608.79, 556.31, 488.89, 506.91,
|
||
804.89, 1141.98, 1056.97, 992.46, 1155.99, 827.01, 1257.98, 1232.67,
|
||
871.26, 860.88, 1158.03, 1222.72, 1221.04, 949.99, 987.01, 733.99,
|
||
592.97
|
||
],
|
||
"pv_prognose_wh": [
|
||
0, 0, 0, 0, 0, 0, 0, 8.05, 352.91, 728.51, 930.28, 1043.25, 1106.74,
|
||
1161.69, 6018.82, 5519.07, 3969.88, 3017.96, 1943.07, 1007.17,
|
||
319.67, 7.88, 0, 0, 0, 0, 0, 0, 0, 0, 0, 5.04, 335.59, 705.32,
|
||
1121.12, 1604.79, 2157.38, 1433.25, 5718.49, 4553.96, 3027.55,
|
||
2574.46, 1720.4, 963.4, 383.3, 0, 0, 0
|
||
],
|
||
"strompreis_euro_pro_wh": [
|
||
0.0003384, 0.0003318, 0.0003284, 0.0003283, 0.0003289, 0.0003334,
|
||
0.0003290, 0.0003302, 0.0003042, 0.0002430, 0.0002280, 0.0002212,
|
||
0.0002093, 0.0001879, 0.0001838, 0.0002004, 0.0002198, 0.0002270,
|
||
0.0002997, 0.0003195, 0.0003081, 0.0002969, 0.0002921, 0.0002780,
|
||
0.0003384, 0.0003318, 0.0003284, 0.0003283, 0.0003289, 0.0003334,
|
||
0.0003290, 0.0003302, 0.0003042, 0.0002430, 0.0002280, 0.0002212,
|
||
0.0002093, 0.0001879, 0.0001838, 0.0002004, 0.0002198, 0.0002270,
|
||
0.0002997, 0.0003195, 0.0003081, 0.0002969, 0.0002921, 0.0002780
|
||
]
|
||
},
|
||
"pv_akku": {
|
||
"device_id": "battery1",
|
||
"capacity_wh": 26400,
|
||
"max_charge_power_w": 5000,
|
||
"initial_soc_percentage": 80,
|
||
"min_soc_percentage": 15
|
||
},
|
||
"inverter": {
|
||
"device_id": "inverter1",
|
||
"max_power_wh": 10000,
|
||
"battery_id": "battery1",
|
||
"ac_to_dc_efficiency": 0.95,
|
||
"dc_to_ac_efficiency": 0.95,
|
||
"max_ac_charge_power_w": 5000
|
||
},
|
||
"eauto": {
|
||
"device_id": "ev1",
|
||
"capacity_wh": 60000,
|
||
"charging_efficiency": 0.95,
|
||
"charge_rates": [0.0, 0.375, 0.5, 0.625, 0.75, 0.875, 1.0],
|
||
"discharging_efficiency": 1.0,
|
||
"max_charge_power_w": 11040,
|
||
"initial_soc_percentage": 54,
|
||
"min_soc_percentage": 0
|
||
},
|
||
"temperature_forecast": [
|
||
18.3, 17.8, 16.9, 16.2, 15.6, 15.1, 14.6, 14.2, 14.3, 14.8, 15.7, 16.7, 17.4,
|
||
18.0, 18.6, 19.2, 19.1, 18.7, 18.5, 17.7, 16.2, 14.6, 13.6, 13.0, 12.6, 12.2,
|
||
11.7, 11.6, 11.3, 11.0, 10.7, 10.2, 11.4, 14.4, 16.4, 18.3, 19.5, 20.7, 21.9,
|
||
22.7, 23.1, 23.1, 22.8, 21.8, 20.2, 19.1, 18.0, 17.4
|
||
],
|
||
"start_solution": null
|
||
}
|
||
```
|
||
|
||
## Input Parameters
|
||
|
||
### Energy Management System (EMS)
|
||
|
||
#### Battery Cost (`preis_euro_pro_wh_akku`)
|
||
|
||
- Unit: €/Wh
|
||
- Purpose: Represents the residual value of energy stored in the battery
|
||
- Impact: Lower values encourage battery depletion, higher values preserve charge at the end of the
|
||
simulation.
|
||
|
||
#### Feed-in Tariff (`einspeiseverguetung_euro_pro_wh`)
|
||
|
||
- Unit: €/Wh
|
||
- Purpose: Compensation received for feeding excess energy back to the grid
|
||
|
||
#### Total Load Forecast (`gesamtlast`)
|
||
|
||
- Unit: W
|
||
- Time Range: 48 hours (00:00 today to 23:00 tomorrow)
|
||
- Format: Array of hourly values
|
||
- Note: Exclude optimizable loads (EV charging, battery charging, etc.)
|
||
|
||
##### Data Sources
|
||
|
||
1. Standard Load Profile: `GET /v1/prediction/list?key=load_mean` for a standard load profile based
|
||
on your yearly consumption.
|
||
2. Adjusted Load Profile: `GET /v1/prediction/list?key=load_mean_adjusted` for a combination of a
|
||
standard load profile based on your yearly consumption incl. data from last 48h.
|
||
|
||
#### PV Generation Forecast (`pv_prognose_wh`)
|
||
|
||
- Unit: W
|
||
- Time Range: 48 hours (00:00 today to 23:00 tomorrow)
|
||
- Format: Array of hourly values
|
||
- Data Source: `GET /v1/prediction/series?key=pvforecast_ac_power`
|
||
|
||
#### Electricity Price Forecast (`strompreis_euro_pro_wh`)
|
||
|
||
- Unit: €/Wh
|
||
- Time Range: 48 hours (00:00 today to 23:00 tomorrow)
|
||
- Format: Array of hourly values
|
||
- Data Source: `GET /v1/prediction/list?key=elecprice_marketprice_wh`
|
||
|
||
Verify prices against your local tariffs.
|
||
|
||
### Battery Storage System
|
||
|
||
#### Configuration
|
||
|
||
- `device_id`: ID of battery
|
||
- `capacity_wh`: Total battery capacity in Wh
|
||
- `charging_efficiency`: Charging efficiency (0-1)
|
||
- `discharging_efficiency`: Discharging efficiency (0-1)
|
||
- `max_charge_power_w`: Maximum charging power in W
|
||
|
||
#### State of Charge (SoC)
|
||
|
||
- `initial_soc_percentage`: Current battery level (%)
|
||
- `min_soc_percentage`: Minimum allowed SoC (%)
|
||
- `max_soc_percentage`: Maximum allowed SoC (%)
|
||
|
||
### Inverter
|
||
|
||
- `device_id`: ID of inverter
|
||
- `max_power_wh`: Maximum inverter power in Wh
|
||
- `battery_id`: ID of battery
|
||
- `ac_to_dc_efficiency`: Efficiency of AC→DC conversion for grid-to-battery AC charging (0-1).
|
||
Set to `0` to disable AC charging via inverter. Default `1.0` (backward compatible, no additional
|
||
inverter loss — existing battery `charging_efficiency` applies).
|
||
- `dc_to_ac_efficiency`: Efficiency of DC→AC conversion for battery discharging to AC load/grid
|
||
(0-1). Must be > 0. Default `1.0` (backward compatible).
|
||
- `max_ac_charge_power_w`: Maximum AC charging power in watts. `null` means no additional limit
|
||
(battery's own `max_charge_power_w` applies). Set to `0` to disable AC charging. Default `null`.
|
||
|
||
#### Efficiency Model
|
||
|
||
The inverter efficiency parameters cleanly separate the **DC battery efficiency** from the
|
||
**AC↔DC inverter conversion efficiency**:
|
||
|
||
- **DC charging from PV surplus**: PV → Battery (direct DC, only `charging_efficiency` applies)
|
||
- **AC charging from grid**: Grid (AC) → Inverter (`ac_to_dc_efficiency`) → Battery
|
||
(`charging_efficiency`)
|
||
- **Discharging to AC load/grid**: Battery (`discharging_efficiency`) → Inverter
|
||
(`dc_to_ac_efficiency`) → Load/Grid (AC)
|
||
|
||
Round-trip efficiency for AC charging and discharging:
|
||
`η_round_trip = ac_to_dc_efficiency × charging_efficiency × discharging_efficiency × dc_to_ac_efficiency`
|
||
|
||
For profitability, the discharge electricity price must exceed:
|
||
`buy_price / η_round_trip`
|
||
|
||
**Backward compatibility**: With default values (`ac_to_dc_efficiency=1.0`,
|
||
`dc_to_ac_efficiency=1.0`, `max_ac_charge_power_w=null`), existing configurations work identically.
|
||
To model realistic inverter losses, set both efficiencies to a value like `0.95` and adjust
|
||
battery efficiencies to reflect pure DC losses only (typically `0.96`–`0.99` for Li-ion).
|
||
|
||
#### AC Charging Break-Even Penalty
|
||
|
||
The genetic optimizer includes an economic break-even check as a fitness penalty to guide
|
||
convergence away from unprofitable AC grid charging. For each scheduled AC charging hour the
|
||
optimizer checks whether the best future discharge price (after accounting for round-trip losses)
|
||
actually recovers the charging cost.
|
||
|
||
**Free PV energy handling**: Energy already stored in the battery from PV generation (zero
|
||
grid cost) is treated as a free resource that covers the most expensive future hours first.
|
||
AC grid charging is only evaluated against the *remaining* uncovered hours.
|
||
|
||
The penalty magnitude is:
|
||
|
||
```text
|
||
penalty = ac_wh_charged × (break_even_price − best_uncovered_price) × factor
|
||
```
|
||
|
||
where:
|
||
- `break_even_price = charge_price / η_round_trip`
|
||
- `best_uncovered_price` = highest future price not already covered by free PV battery energy
|
||
- `factor` = `optimization.genetic.penalties.ac_charge_break_even` (default `1.0`)
|
||
|
||
The penalty does not replace the simulation cost — it amplifies the economic loss signal so the
|
||
algorithm converges faster away from unprofitable charging regions.
|
||
|
||
To tune the aggressiveness of this penalty, set `penalties.ac_charge_break_even` in the
|
||
optimization configuration. A value of `1.0` corresponds to the exact economic loss in €.
|
||
Larger values (e.g. `3.0`) make the algorithm more aggressively avoid unprofitable AC charging;
|
||
smaller values (e.g. `0.0`) disable the penalty entirely.
|
||
|
||
### Electric Vehicle (EV)
|
||
|
||
- `device_id`: ID of electric vehicle
|
||
- `capacity_wh`: Battery capacity in Wh
|
||
- `charging_efficiency`: Charging efficiency (0-1)
|
||
- `discharging_efficiency`: Discharging efficiency (0-1)
|
||
- `max_charge_power_w`: Maximum charging power in W
|
||
- `initial_soc_percentage`: Current charge level (%)
|
||
- `min_soc_percentage`: Minimum allowed SoC (%)
|
||
- `max_soc_percentage`: Maximum allowed SoC (%)
|
||
|
||
### Temperature Forecast
|
||
|
||
- Unit: °C
|
||
- Time Range: 48 hours (00:00 today to 23:00 tomorrow)
|
||
- Format: Array of hourly values
|
||
- Data Source: `GET /v1/prediction/list?key=weather_temp_air`
|
||
|
||
## Output Format
|
||
|
||
### Sample Response
|
||
|
||
```json
|
||
{
|
||
"ac_charge": [0.625, 0, ..., 0.75, 0],
|
||
"dc_charge": [1, 1, ..., 1, 1],
|
||
"discharge_allowed": [0, 0, 1, ..., 0, 0],
|
||
"eautocharge_hours_float": [0.625, 0, ..., 0.75, 0],
|
||
"result": {
|
||
"Last_Wh_pro_Stunde": [...],
|
||
"EAuto_SoC_pro_Stunde": [...],
|
||
"Einnahmen_Euro_pro_Stunde": [...],
|
||
"Gesamt_Verluste": 1514.96,
|
||
"Gesamtbilanz_Euro": 2.51,
|
||
"Gesamteinnahmen_Euro": 2.88,
|
||
"Gesamtkosten_Euro": 5.39,
|
||
"akku_soc_pro_stunde": [...]
|
||
}
|
||
}
|
||
```
|
||
|
||
### Output Parameters
|
||
|
||
#### Battery Control
|
||
|
||
- `ac_charge`: Grid charging schedule (0.0-1.0)
|
||
- `dc_charge`: DC charging schedule (0-1)
|
||
- `discharge_allowed`: Discharge permission (0 or 1)
|
||
|
||
0 (no charge)
|
||
1 (charge with full load)
|
||
|
||
`ac_charge` multiplied by the maximum charge power of the battery results in the planned charging
|
||
power.
|
||
|
||
#### EV Charging
|
||
|
||
- `eautocharge_hours_float`: EV charging schedule (0.0-1.0)
|
||
|
||
#### Results
|
||
|
||
The `result` object contains detailed information about the optimization outcome. The length of the
|
||
array is between 25 and 48 and starts at the current hour and ends at 23:00 tomorrow.
|
||
|
||
- `Last_Wh_pro_Stunde`: Array of hourly load values in Wh
|
||
- Shows the total energy consumption per hour
|
||
- Includes household load, battery charging/discharging, and EV charging
|
||
|
||
- `EAuto_SoC_pro_Stunde`: Array of hourly EV state of charge values (%)
|
||
- Shows the projected EV battery level throughout the optimization period
|
||
|
||
- `Einnahmen_Euro_pro_Stunde`: Array of hourly revenue values in Euro
|
||
|
||
- `Gesamt_Verluste`: Total energy losses in Wh
|
||
|
||
- `Gesamtbilanz_Euro`: Overall financial balance in Euro
|
||
|
||
- `Gesamteinnahmen_Euro`: Total revenue in Euro
|
||
|
||
- `Gesamtkosten_Euro`: Total costs in Euro
|
||
|
||
- `akku_soc_pro_stunde`: Array of hourly battery state of charge values (%)
|
||
|
||
## Timeframe overview
|
||
|
||
```{figure} ../_static/optimization_timeframes.png
|
||
:alt: Timeframe Overview
|
||
|
||
Timeframe Overview
|
||
```
|