A battery profile describes a battery model: the charge and discharge limit
maps over temperature and SoC, the charge and discharge efficiency curves
over C-rate, the technical SoC bounds, the hard temperature cutoffs and,
for a model, its nominal capacity and power limits. EOS packages the
generic profile generic-lfp; users add their own profiles.
A battery or electric vehicle selects its profile by battery_profile and
describes how the installation differs from it in profile_adjustment
(capacity, power limits of the installation, periodic full charge). The
effective values are resolved from both at the measured operating point
(temperature, SoC, power) and shown as effective_* fields.
The GENETIC simulation uses the limits and efficiencies of the profile over
SoC, with precomputed tables as a fast path; GENETIC0 gets the values at the
operating point. Optimization parameters are always valid: a battery whose
profile is missing, unreadable or invalid uses the packaged generic-lfp
profile, and the former defaults only if that is not usable either; each is
logged as error, and an optimization run is never cancelled because of a
battery.
Additional changes
- Add a generic device profile store: user and packaged profiles, atomic
saves, compiled profiles cached per file and checked again at most once a
second, plain file names as profile names ('schema' is reserved). On
Windows, a save or read that collides with the other is retried briefly.
- Add the REST API /v1/profile to list the profile kinds and to list, read
(document and JSON schema), save and delete profiles.
- Check the hard temperature cutoffs on the exact temperature.
- Resolve inhibited charging or discharging to a power of 0, e.g. for a cold
battery; give GENETIC0 its own discharge limit for that.
- Limit generic profiles without own power limits to the former 5000 W.
- Accept only the implemented units; current limits need the nominal
voltage.
- Migrate legacy battery settings into the profile adjustment, keep the
former charge power limit as discharge limit (also for a Home Assistant
entity on it) and report dropped efficiencies as errors.
- Limit GENETIC battery discharge by the discharge power.
- Allow battery profile lookups while the configuration is created.
- Resolve a battery once per configuration dump.
- Package the bundled profiles, document battery profiles and regenerate
the configuration and OpenAPI documentation.
- Ignore the report PDFs written by the visualization tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
1862 lines
86 KiB
Python
1862 lines
86 KiB
Python
"""Tests for the batterysettings module.
|
|
|
|
The module exercises the configuration fields of BatteriesCommonSettings, the
|
|
computed fields that are evaluated on access at the reference operating point,
|
|
the battery profile that is always present (default ``generic-lfp``), the
|
|
operating point and the charge / discharge power read asynchronously from
|
|
measurements, and the conversion to the GENETIC and GENETIC0 optimization
|
|
parameters.
|
|
|
|
The battery profile loader and the measurement access are replaced by autouse
|
|
fixtures, so most tests do not depend on the configuration singleton, the
|
|
measurement store or the packaged data directory. Unless a test installs another
|
|
profile, settings use a plain profile (8000 Wh, charge 0.5 C, discharge 0.4 C,
|
|
flat efficiency curves of 0.88, technical SoC bounds 0 % and 100 %) and no
|
|
measurement is available. TestMeasurementAccess uses the real measurement store.
|
|
"""
|
|
|
|
import dataclasses
|
|
from typing import Any, Optional
|
|
|
|
import pytest
|
|
from pydantic import ValidationError
|
|
|
|
from akkudoktoreos.devices.profile.batteryprofile import (
|
|
Axes,
|
|
BatteryProfile,
|
|
BatteryProfileSettings,
|
|
ChargeDischargeLimitMap,
|
|
EfficiencyCurve,
|
|
HardCutoffs,
|
|
OutOfRangeBehavior,
|
|
Units,
|
|
)
|
|
from akkudoktoreos.devices.profile.profilestore import get_profile_store
|
|
from akkudoktoreos.devices.settings import batterymeasurement
|
|
from akkudoktoreos.devices.settings.batterysettings import (
|
|
BATTERY_DEFAULT_PROFILE,
|
|
BATTERY_DEFAULT_SOC_FACTOR,
|
|
BATTERY_DEFAULT_TEMPERATURE_DEGC,
|
|
BatteriesCommonSettings,
|
|
BatteryOperatingParameters,
|
|
BatteryOperatingPoint,
|
|
BatteryProfileAdjustment,
|
|
BatteryResolutionError,
|
|
)
|
|
|
|
# The real measurement accessor, captured before any fixture replaces it.
|
|
REAL_GET_MEASURED_VALUE = batterymeasurement.get_measured_value
|
|
|
|
# Capacity and flat efficiency of the plain test profile.
|
|
PROFILE_CAPACITY_WH = 8000
|
|
PROFILE_EFFICIENCY = 0.88
|
|
|
|
# Axes of the test profiles: temperatures [-10, -5, 0, 5, 10, 15, 25, 35, 45, 50],
|
|
# SoC [0, 5, 10, 20, 40, 60, 80, 90, 95, 100].
|
|
TEST_AXES = {
|
|
"temperature_degC": [-10, -5, 0, 5, 10, 15, 25, 35, 45, 50],
|
|
"soc_percent": [0, 5, 10, 20, 40, 60, 80, 90, 95, 100],
|
|
}
|
|
# Hard cutoffs of the test profiles: charging -10 ... 55 degC, discharging -15 ... 60 degC.
|
|
TEST_CUTOFFS = {
|
|
"charge_allowed_below_degC": -10.0,
|
|
"charge_allowed_above_degC": 55.0,
|
|
"discharge_allowed_below_degC": -15.0,
|
|
"discharge_allowed_above_degC": 60.0,
|
|
}
|
|
ROW_0_DEGC = 2
|
|
ROW_25_DEGC = 6
|
|
COLUMN_40_PERCENT = 4
|
|
COLUMN_60_PERCENT = 5
|
|
|
|
PARAMETER_METHODS = [
|
|
"to_genetic_pv_bat_param",
|
|
"to_genetic_ev_bat_param",
|
|
"to_genetic0_pv_bat_param",
|
|
"to_genetic0_ev_bat_param",
|
|
]
|
|
|
|
COMPUTED_FIELDS = [
|
|
"effective_nominal_capacity_wh",
|
|
"effective_max_charge_power_w",
|
|
"effective_max_discharge_power_w",
|
|
"effective_charging_efficiency",
|
|
"effective_discharging_efficiency",
|
|
"effective_min_soc_percentage",
|
|
"effective_max_soc_percentage",
|
|
]
|
|
|
|
# Fields that moved into the profile adjustment: (former field, adjustment field).
|
|
MOVED_TO_ADJUSTMENT = [
|
|
("nominal_capacity_wh", "nominal_capacity_wh"),
|
|
("max_charge_power_limit_w", "max_charge_power_w"),
|
|
("max_discharge_power_limit_w", "max_discharge_power_w"),
|
|
]
|
|
|
|
# Computed fields that used to read measurements and are gone now.
|
|
REMOVED_COMPUTED_FIELDS = ["current_soc_factor", "current_temperature_degc"]
|
|
|
|
# Fields that used to be configuration fields and are computed now.
|
|
FORMER_CONFIGURATION_FIELDS = [
|
|
"capacity_wh",
|
|
"charging_efficiency",
|
|
"discharging_efficiency",
|
|
"max_charge_power_w",
|
|
"max_discharge_power_w",
|
|
]
|
|
|
|
|
|
# --- helpers -------------------------------------------------------------
|
|
|
|
|
|
def make_grid(value: float, rows: int = 10, cols: int = 10) -> list[list[float]]:
|
|
"""Return a constant rows x cols grid filled with value."""
|
|
return [[value for _ in range(cols)] for _ in range(rows)]
|
|
|
|
|
|
def make_profile_config(
|
|
charge: float | list[list[float]] = 0.5,
|
|
discharge: float | list[list[float]] = 0.4,
|
|
**overrides: Any,
|
|
) -> BatteryProfileSettings:
|
|
"""Build a validated BatteryProfileSettings.
|
|
|
|
Without overrides the profile is the plain test profile: 8000 Wh, flat
|
|
efficiency curves of 0.88, technical SoC bounds 0 % and 100 %, C-rate limits.
|
|
|
|
Args:
|
|
charge: Constant charge limit or a full 10 x 10 grid.
|
|
discharge: Constant discharge limit or a full 10 x 10 grid.
|
|
**overrides: Further keyword arguments forwarded to the model, e.g.
|
|
``nominal_capacity_wh=None`` for a generic profile.
|
|
|
|
Returns:
|
|
A validated BatteryProfileSettings instance.
|
|
"""
|
|
charge_values = make_grid(charge) if isinstance(charge, (int, float)) else charge
|
|
discharge_values = make_grid(discharge) if isinstance(discharge, (int, float)) else discharge
|
|
payload: dict[str, Any] = dict(
|
|
battery_model="Test Battery",
|
|
nominal_capacity_wh=float(PROFILE_CAPACITY_WH),
|
|
technical_min_soc_percent=0.0,
|
|
technical_max_soc_percent=100.0,
|
|
charge_efficiency=make_curve([0.0, 2.0], [PROFILE_EFFICIENCY, PROFILE_EFFICIENCY]),
|
|
discharge_efficiency=make_curve([0.0, 2.0], [PROFILE_EFFICIENCY, PROFILE_EFFICIENCY]),
|
|
units=Units(limit="C-rate"),
|
|
axes=Axes.model_validate(TEST_AXES),
|
|
hard_cutoffs=HardCutoffs.model_validate(TEST_CUTOFFS),
|
|
charge_limit_crate=ChargeDischargeLimitMap(values=charge_values),
|
|
discharge_limit_crate=ChargeDischargeLimitMap(values=discharge_values),
|
|
)
|
|
payload.update(overrides)
|
|
return BatteryProfileSettings(**payload)
|
|
|
|
|
|
def make_profile(
|
|
charge: float | list[list[float]] = 0.5,
|
|
discharge: float | list[list[float]] = 0.4,
|
|
**overrides: Any,
|
|
) -> BatteryProfile:
|
|
"""Build a ready-to-use BatteryProfile, see make_profile_config."""
|
|
return make_profile_config(charge, discharge, **overrides).to_limits()
|
|
|
|
|
|
def make_curve(c_rate: list[float], efficiency: list[float]) -> EfficiencyCurve:
|
|
"""Build a validated efficiency curve with linear interpolation."""
|
|
return EfficiencyCurve(c_rate=c_rate, efficiency=efficiency)
|
|
|
|
|
|
def charge_inhibited_below_30() -> HardCutoffs:
|
|
"""Cutoffs that inhibit charging at the default temperature of 25 degC."""
|
|
return HardCutoffs.model_validate(
|
|
{**TEST_CUTOFFS, "charge_allowed_below_degC": 30.0, "charge_allowed_above_degC": 55.0}
|
|
)
|
|
|
|
|
|
def discharge_inhibited_below_30() -> HardCutoffs:
|
|
"""Cutoffs that inhibit discharging at the default temperature of 25 degC."""
|
|
return HardCutoffs.model_validate(
|
|
{
|
|
**TEST_CUTOFFS,
|
|
"discharge_allowed_below_degC": 30.0,
|
|
"discharge_allowed_above_degC": 60.0,
|
|
}
|
|
)
|
|
|
|
|
|
def make_settings(**overrides: Any) -> BatteriesCommonSettings:
|
|
"""Build a BatteriesCommonSettings with device_id battery1.
|
|
|
|
The keyword arguments ``capacity_wh``, ``charge_limit_w`` and
|
|
``discharge_limit_w`` go into the profile adjustment as
|
|
``nominal_capacity_wh``, ``max_charge_power_w`` and ``max_discharge_power_w``.
|
|
"""
|
|
adjustment: dict[str, Any] = {}
|
|
for short_name, name in (
|
|
("capacity_wh", "nominal_capacity_wh"),
|
|
("charge_limit_w", "max_charge_power_w"),
|
|
("discharge_limit_w", "max_discharge_power_w"),
|
|
):
|
|
if short_name in overrides:
|
|
adjustment[name] = overrides.pop(short_name)
|
|
payload: dict[str, Any] = {"device_id": "battery1"}
|
|
if adjustment:
|
|
payload["profile_adjustment"] = adjustment
|
|
payload.update(overrides)
|
|
return BatteriesCommonSettings(**payload)
|
|
|
|
|
|
async def current(settings: BatteriesCommonSettings) -> BatteryOperatingParameters:
|
|
"""Resolve the parameters at the measured operating point."""
|
|
return await settings.resolve_current_operating_parameters()
|
|
|
|
|
|
# --- fixtures ------------------------------------------------------------
|
|
|
|
|
|
@pytest.fixture(autouse=True)
|
|
def measurements(monkeypatch: pytest.MonkeyPatch) -> dict[str, Optional[float]]:
|
|
"""Replace the measurement access by a dict keyed by measurement key.
|
|
|
|
Keys missing from the dict yield None, i.e. no measurement available.
|
|
The dict is returned, so tests set values like
|
|
``measurements["battery1-soc-factor"] = 0.4`` at any time.
|
|
"""
|
|
values: dict[str, Optional[float]] = {}
|
|
|
|
async def fake_get_measured_value(key: str, target_datetime: Any) -> Optional[float]:
|
|
return values.get(key)
|
|
|
|
monkeypatch.setattr(batterymeasurement, "get_measured_value", fake_get_measured_value)
|
|
return values
|
|
|
|
|
|
@pytest.fixture
|
|
def measurement_calls(monkeypatch: pytest.MonkeyPatch) -> list[str]:
|
|
"""Record every measurement query, answering None for all of them."""
|
|
calls: list[str] = []
|
|
|
|
async def fake_get_measured_value(key: str, target_datetime: Any) -> Optional[float]:
|
|
calls.append(key)
|
|
return None
|
|
|
|
monkeypatch.setattr(batterymeasurement, "get_measured_value", fake_get_measured_value)
|
|
return calls
|
|
|
|
|
|
@pytest.fixture
|
|
def install_profile(monkeypatch: pytest.MonkeyPatch):
|
|
"""Return a function that makes the profile store return a given profile.
|
|
|
|
The returned function yields the list of profile names that were requested,
|
|
so tests can assert how often the loader ran. Calling it again replaces the
|
|
previously installed profile.
|
|
"""
|
|
|
|
def _install(profile: Any) -> list[str]:
|
|
calls: list[str] = []
|
|
|
|
def fake_get(document_type: Any, name: str, **options: Any) -> Any:
|
|
calls.append(name)
|
|
return profile
|
|
|
|
monkeypatch.setattr(get_profile_store(), "get", fake_get)
|
|
return calls
|
|
|
|
return _install
|
|
|
|
|
|
@pytest.fixture
|
|
def broken_profile_loader(monkeypatch: pytest.MonkeyPatch) -> None:
|
|
"""Make every profile load fail with FileNotFoundError."""
|
|
|
|
def missing(document_type, name, **options):
|
|
raise FileNotFoundError(f"No battery profile for '{name}'")
|
|
|
|
monkeypatch.setattr(get_profile_store(), "get", missing)
|
|
|
|
|
|
@pytest.fixture(autouse=True)
|
|
def _plain_default_profile(install_profile) -> None:
|
|
"""Install the plain profile that settings use unless a test installs another."""
|
|
install_profile(make_profile())
|
|
|
|
|
|
@pytest.fixture
|
|
def make_profiled_settings(install_profile):
|
|
"""Return a factory for settings that use the given in-memory profile."""
|
|
|
|
def _make(profile: Any, **overrides: Any) -> BatteriesCommonSettings:
|
|
install_profile(profile)
|
|
return make_settings(**overrides)
|
|
|
|
return _make
|
|
|
|
|
|
@pytest.fixture
|
|
def full_profile() -> BatteryProfile:
|
|
"""Profile with efficiency curves and technical SoC bounds.
|
|
|
|
At the default operating point: charge 0.5 C, discharge 0.4 C.
|
|
"""
|
|
return make_profile(
|
|
charge_efficiency=make_curve([0.1, 0.5, 1.0], [0.90, 0.96, 0.92]),
|
|
discharge_efficiency=make_curve([0.1, 0.5], [0.90, 0.95]),
|
|
technical_min_soc_percent=5.0,
|
|
technical_max_soc_percent=95.0,
|
|
)
|
|
|
|
|
|
# --- Defaults and validation ------------------------------------------------
|
|
|
|
|
|
class TestDefaultsAndValidation:
|
|
"""Tests for field defaults and validation."""
|
|
|
|
def test_default_battery_profile(self):
|
|
assert BATTERY_DEFAULT_PROFILE == "generic-lfp"
|
|
assert make_settings().battery_profile == "generic-lfp"
|
|
|
|
def test_battery_profile_is_not_optional(self):
|
|
with pytest.raises(ValidationError):
|
|
make_settings(battery_profile=None)
|
|
|
|
def test_battery_profile_must_not_be_empty(self):
|
|
with pytest.raises(ValidationError):
|
|
make_settings(battery_profile="")
|
|
|
|
def test_profile_adjustment_defaults_to_no_adjustment(self):
|
|
settings = make_settings()
|
|
assert settings.profile_adjustment.model_dump() == BatteryProfileAdjustment().model_dump()
|
|
assert settings.profile_adjustment.nominal_capacity_wh is None
|
|
assert settings.profile_adjustment.max_charge_power_w is None
|
|
assert settings.profile_adjustment.max_discharge_power_w is None
|
|
|
|
def test_old_name_battery_model_is_gone(self):
|
|
assert "battery_model" not in BatteriesCommonSettings.model_fields
|
|
assert "battery_profile" in BatteriesCommonSettings.model_fields
|
|
|
|
@pytest.mark.parametrize("field", FORMER_CONFIGURATION_FIELDS)
|
|
def test_former_configuration_fields_are_not_fields_any_more(self, field):
|
|
assert field not in BatteriesCommonSettings.model_fields
|
|
|
|
@pytest.mark.parametrize("former, adjustment_field", MOVED_TO_ADJUSTMENT)
|
|
def test_fields_moved_into_the_profile_adjustment(self, former, adjustment_field):
|
|
assert former not in BatteriesCommonSettings.model_fields
|
|
assert adjustment_field in BatteryProfileAdjustment.model_fields
|
|
|
|
def test_adjustment_fields_are_named_after_profile_fields(self):
|
|
for name in BatteryProfileAdjustment.model_fields:
|
|
assert name in BatteryProfileSettings.model_fields
|
|
|
|
def test_operating_point_defaults(self):
|
|
assert BATTERY_DEFAULT_SOC_FACTOR == pytest.approx(0.5)
|
|
assert BATTERY_DEFAULT_TEMPERATURE_DEGC == pytest.approx(25.0)
|
|
|
|
def test_unusable_profile_resolves_to_none(self, broken_profile_loader):
|
|
settings = make_settings()
|
|
for field in COMPUTED_FIELDS:
|
|
assert getattr(settings, field) is None
|
|
|
|
def test_unusable_profile_raises_naming_the_battery(self, broken_profile_loader):
|
|
with pytest.raises(BatteryResolutionError, match="Battery 'battery1'"):
|
|
make_settings().resolve_operating_parameters()
|
|
|
|
@pytest.mark.parametrize("value", [0, -1])
|
|
def test_rejects_non_positive_nominal_capacity(self, value):
|
|
with pytest.raises(ValidationError):
|
|
make_settings(capacity_wh=value)
|
|
|
|
@pytest.mark.parametrize("field", ["charge_limit_w", "discharge_limit_w"])
|
|
@pytest.mark.parametrize("value", [0, -1.0])
|
|
def test_rejects_non_positive_power_limits(self, field, value):
|
|
with pytest.raises(ValidationError):
|
|
make_settings(**{field: value})
|
|
|
|
def test_rejects_min_soc_above_max_soc(self):
|
|
with pytest.raises(ValidationError, match="min_soc_percentage"):
|
|
make_settings(min_soc_percentage=80, max_soc_percentage=20)
|
|
|
|
def test_rejects_min_charge_power_above_installation_limit(self):
|
|
with pytest.raises(ValidationError, match="min_charge_power_w"):
|
|
make_settings(min_charge_power_w=6000.0, charge_limit_w=5000.0)
|
|
|
|
def test_min_charge_power_without_installation_limit_is_accepted(self):
|
|
# The profile decides the limit, which is not known at validation time.
|
|
settings = make_settings(min_charge_power_w=6000.0)
|
|
assert settings.profile_adjustment.max_charge_power_w is None
|
|
|
|
|
|
class TestJsonSchema:
|
|
"""Tests for the schema of configuration fields and computed fields."""
|
|
|
|
@pytest.mark.parametrize("field", ["battery_profile", "profile_adjustment"])
|
|
def test_configuration_fields_are_documented(self, field):
|
|
schema = BatteriesCommonSettings.model_json_schema()
|
|
assert schema["properties"][field]["description"]
|
|
assert schema["properties"][field]["examples"]
|
|
|
|
@pytest.mark.parametrize(
|
|
"field", ["nominal_capacity_wh", "max_charge_power_w", "max_discharge_power_w"]
|
|
)
|
|
def test_adjustment_fields_are_documented(self, field):
|
|
schema = BatteryProfileAdjustment.model_json_schema()
|
|
assert schema["properties"][field]["description"]
|
|
assert schema["properties"][field]["examples"]
|
|
|
|
def test_profile_and_adjustment_are_not_required(self):
|
|
schema = BatteriesCommonSettings.model_json_schema()
|
|
assert schema["properties"]["battery_profile"]["default"] == "generic-lfp"
|
|
assert "battery_profile" not in schema.get("required", [])
|
|
assert "profile_adjustment" not in schema.get("required", [])
|
|
|
|
@pytest.mark.parametrize("field", FORMER_CONFIGURATION_FIELDS)
|
|
def test_former_configuration_fields_are_not_in_validation_schema(self, field):
|
|
schema = BatteriesCommonSettings.model_json_schema(mode="validation")
|
|
assert field not in schema["properties"]
|
|
|
|
@pytest.mark.parametrize("field", COMPUTED_FIELDS)
|
|
def test_computed_fields_are_part_of_serialization_schema(self, field):
|
|
schema = BatteriesCommonSettings.model_json_schema(mode="serialization")
|
|
assert field in schema["properties"]
|
|
|
|
def test_capacity_wh_is_neither_field_nor_computed_field(self):
|
|
"""'capacity_wh' must not appear in settings, dumps or schemas.
|
|
|
|
An old config file containing 'capacity_wh' is then unambiguously legacy.
|
|
"""
|
|
assert "capacity_wh" not in BatteriesCommonSettings.model_fields
|
|
assert "capacity_wh" not in BatteriesCommonSettings.model_computed_fields
|
|
for mode in ("validation", "serialization"):
|
|
schema = BatteriesCommonSettings.model_json_schema(mode=mode)
|
|
assert "capacity_wh" not in schema["properties"]
|
|
assert "capacity_wh" not in make_settings().model_dump()
|
|
|
|
|
|
# --- Computed fields ----------------------------------------------------------------
|
|
|
|
|
|
class TestComputedFieldEvaluation:
|
|
"""Tests that computed fields are evaluated on access and never raise."""
|
|
|
|
def test_not_evaluated_during_construction(self, measurement_calls, install_profile):
|
|
calls = install_profile(make_profile())
|
|
make_settings(capacity_wh=10000)
|
|
assert measurement_calls == []
|
|
assert calls == []
|
|
|
|
def test_not_evaluated_by_reading_configuration_fields(self, measurement_calls):
|
|
settings = make_settings(capacity_wh=10000)
|
|
_ = settings.profile_adjustment.nominal_capacity_wh
|
|
_ = settings.battery_profile
|
|
assert measurement_calls == []
|
|
|
|
def test_never_read_measurements(self, measurement_calls):
|
|
settings = make_settings()
|
|
for field in COMPUTED_FIELDS:
|
|
_ = getattr(settings, field)
|
|
settings.model_dump()
|
|
settings.model_dump_json()
|
|
assert measurement_calls == []
|
|
|
|
@pytest.mark.parametrize("field", REMOVED_COMPUTED_FIELDS)
|
|
def test_measurement_based_computed_fields_are_gone(self, field):
|
|
assert field not in BatteriesCommonSettings.model_computed_fields
|
|
assert field not in make_settings().model_dump()
|
|
|
|
def test_follows_changed_configuration(self):
|
|
settings = make_settings(capacity_wh=10000)
|
|
assert settings.effective_nominal_capacity_wh == 10000
|
|
assert settings.effective_max_charge_power_w == pytest.approx(5000.0)
|
|
settings.profile_adjustment.nominal_capacity_wh = 6000
|
|
assert settings.effective_nominal_capacity_wh == 6000
|
|
assert settings.effective_max_charge_power_w == pytest.approx(3000.0)
|
|
settings.profile_adjustment.nominal_capacity_wh = None
|
|
assert settings.effective_nominal_capacity_wh == PROFILE_CAPACITY_WH
|
|
|
|
def test_power_ignores_measured_temperature(self, make_profiled_settings, measurements):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = 0.0
|
|
assert settings.effective_max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
def test_efficiency_ignores_measured_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
assert settings.effective_charging_efficiency == pytest.approx(0.96)
|
|
|
|
def test_model_dump_contains_computed_fields(self):
|
|
dumped = make_settings(capacity_wh=10000).model_dump()
|
|
for field in COMPUTED_FIELDS:
|
|
assert field in dumped
|
|
assert dumped["effective_nominal_capacity_wh"] == 10000
|
|
assert dumped["effective_max_charge_power_w"] == pytest.approx(5000.0)
|
|
assert dumped["effective_max_discharge_power_w"] == pytest.approx(4000.0)
|
|
|
|
def test_model_dump_json_contains_computed_fields(self):
|
|
dumped = make_settings(capacity_wh=10000).model_dump_json()
|
|
assert '"effective_nominal_capacity_wh":10000' in dumped.replace(" ", "")
|
|
|
|
def test_round_trip_keeps_configuration_and_ignores_computed_values(self):
|
|
original = make_settings(
|
|
battery_profile="my-profile", capacity_wh=10000, charge_limit_w=3000.0
|
|
)
|
|
restored = BatteriesCommonSettings.model_validate_json(original.model_dump_json())
|
|
assert restored.battery_profile == "my-profile"
|
|
assert restored.profile_adjustment.nominal_capacity_wh == 10000
|
|
assert restored.profile_adjustment.max_charge_power_w == pytest.approx(3000.0)
|
|
assert restored.effective_nominal_capacity_wh == 10000
|
|
assert restored.effective_max_charge_power_w == pytest.approx(3000.0)
|
|
|
|
def test_serialization_survives_missing_profile(self, broken_profile_loader):
|
|
dumped = make_settings(battery_profile="does-not-exist").model_dump()
|
|
for field in COMPUTED_FIELDS:
|
|
assert dumped[field] is None
|
|
|
|
def test_serialization_survives_inhibited_charging(self, make_profiled_settings):
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
dumped = settings.model_dump()
|
|
# The battery resolves; it may only not charge at the reference point.
|
|
assert dumped["effective_max_charge_power_w"] == 0.0
|
|
assert dumped["effective_nominal_capacity_wh"] == 10000
|
|
|
|
def test_generic_profile_without_capacity_is_not_resolvable(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(nominal_capacity_wh=None))
|
|
assert settings.effective_nominal_capacity_wh is None
|
|
with pytest.raises(BatteryResolutionError, match="profile_adjustment.nominal_capacity_wh"):
|
|
settings.resolve_operating_parameters()
|
|
|
|
def test_generic_profile_takes_capacity_from_adjustment(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(nominal_capacity_wh=None), capacity_wh=6000)
|
|
assert settings.effective_nominal_capacity_wh == 6000
|
|
assert settings.effective_max_charge_power_w == pytest.approx(3000.0)
|
|
|
|
def test_computed_fields_match_strict_resolution(self, make_profiled_settings, full_profile):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert settings.effective_nominal_capacity_wh == resolved.capacity_wh
|
|
assert settings.effective_charging_efficiency == pytest.approx(resolved.charging_efficiency)
|
|
assert settings.effective_discharging_efficiency == pytest.approx(resolved.discharging_efficiency)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(resolved.max_charge_power_w)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(resolved.max_discharge_power_w)
|
|
assert settings.effective_min_soc_percentage == resolved.min_soc_percentage
|
|
assert settings.effective_max_soc_percentage == resolved.max_soc_percentage
|
|
|
|
|
|
# --- Operating point and measurement keys ------------------------------------------
|
|
|
|
|
|
class TestOperatingPoint:
|
|
"""Tests for SoC and temperature taken from measurements."""
|
|
|
|
def test_measurement_keys(self):
|
|
settings = make_settings()
|
|
assert settings.measurement_key_soc_factor == "battery1-soc-factor"
|
|
assert settings.measurement_key_temperature_degc == "battery1-temperature-degc"
|
|
assert settings.measurement_key_charge_power_w == "battery1-charge-power-w"
|
|
assert settings.measurement_key_discharge_power_w == "battery1-discharge-power-w"
|
|
|
|
def test_new_keys_are_listed_in_measurement_keys(self):
|
|
settings = make_settings()
|
|
for key in (
|
|
settings.measurement_key_temperature_degc,
|
|
settings.measurement_key_charge_power_w,
|
|
settings.measurement_key_discharge_power_w,
|
|
):
|
|
assert key in settings.measurement_keys
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_defaults_without_measurement(self):
|
|
point = await make_settings().measure_operating_point()
|
|
assert point == BatteryOperatingPoint()
|
|
assert point.soc_factor == pytest.approx(0.5)
|
|
assert point.temperature_degC == pytest.approx(25.0)
|
|
assert point.charge_power_w is None
|
|
assert point.discharge_power_w is None
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_values_are_used(self, measurements):
|
|
measurements["battery1-soc-factor"] = 0.35
|
|
measurements["battery1-temperature-degc"] = 12.5
|
|
point = await make_settings().measure_operating_point()
|
|
assert point.soc_factor == pytest.approx(0.35)
|
|
assert point.temperature_degC == pytest.approx(12.5)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_only_one_measurement_available(self, measurements):
|
|
measurements["battery1-temperature-degc"] = 10.0
|
|
point = await make_settings().measure_operating_point()
|
|
assert point.soc_factor == pytest.approx(0.5)
|
|
assert point.temperature_degC == pytest.approx(10.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_follows_changed_measurement(self, measurements):
|
|
settings = make_settings()
|
|
measurements["battery1-soc-factor"] = 0.8
|
|
assert (await settings.measure_operating_point()).soc_factor == pytest.approx(0.8)
|
|
measurements["battery1-soc-factor"] = 0.2
|
|
assert (await settings.measure_operating_point()).soc_factor == pytest.approx(0.2)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_reads_every_operating_point_key(self, measurement_calls):
|
|
await make_settings().measure_operating_point()
|
|
assert sorted(measurement_calls) == sorted(
|
|
[
|
|
"battery1-soc-factor",
|
|
"battery1-temperature-degc",
|
|
"battery1-charge-power-w",
|
|
"battery1-discharge-power-w",
|
|
]
|
|
)
|
|
|
|
@pytest.mark.parametrize("measured, expected", [(-0.2, 0.0), (1.3, 1.0)])
|
|
@pytest.mark.asyncio
|
|
async def test_soc_factor_is_clamped(self, measurements, measured, expected):
|
|
measurements["battery1-soc-factor"] = measured
|
|
point = await make_settings().measure_operating_point()
|
|
assert point.soc_factor == pytest.approx(expected)
|
|
|
|
@pytest.mark.parametrize("measured", [float("nan"), float("inf")])
|
|
@pytest.mark.asyncio
|
|
async def test_non_finite_measurements_fall_back_to_defaults(self, measurements, measured):
|
|
measurements["battery1-soc-factor"] = measured
|
|
measurements["battery1-temperature-degc"] = measured
|
|
point = await make_settings().measure_operating_point()
|
|
assert point.soc_factor == pytest.approx(0.5)
|
|
assert point.temperature_degC == pytest.approx(25.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_powers_are_positive_magnitudes(self, measurements):
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
measurements["battery1-discharge-power-w"] = -2000.0
|
|
point = await make_settings().measure_operating_point()
|
|
assert point.charge_power_w == pytest.approx(2500.0)
|
|
assert point.discharge_power_w == pytest.approx(2000.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_keys_follow_device_id(self, measurements):
|
|
measurements["house-battery-soc-factor"] = 0.9
|
|
point = await make_settings(device_id="house-battery").measure_operating_point()
|
|
assert point.soc_factor == pytest.approx(0.9)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_failing_measurement_access_falls_back_to_defaults(self, monkeypatch):
|
|
# Use the real accessor, but let the measurement subsystem fail.
|
|
import akkudoktoreos.core.coreabc as coreabc
|
|
|
|
def broken():
|
|
raise RuntimeError("measurement store not initialised")
|
|
|
|
monkeypatch.setattr(batterymeasurement, "get_measured_value", REAL_GET_MEASURED_VALUE)
|
|
monkeypatch.setattr(coreabc, "get_measurement", broken)
|
|
point = await make_settings().measure_operating_point()
|
|
assert point == BatteryOperatingPoint()
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_profile_is_evaluated_at_measured_temperature(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
assert (await current(settings)).max_charge_power_w == pytest.approx(5000.0)
|
|
measurements["battery1-temperature-degc"] = 0.0
|
|
assert (await current(settings)).max_charge_power_w == pytest.approx(1000.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_profile_is_evaluated_at_measured_soc(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
grid = make_grid(0.5)
|
|
for row in grid:
|
|
row[COLUMN_40_PERCENT] = 0.2
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
measurements["battery1-soc-factor"] = 0.4
|
|
assert (await current(settings)).max_charge_power_w == pytest.approx(2000.0)
|
|
|
|
def test_sync_resolution_ignores_measurements(self, make_profiled_settings, measurements):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = 0.0
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert resolved.temperature_degC == pytest.approx(25.0)
|
|
assert resolved.max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
def test_default_operating_point_is_25_degc_and_half_soc(self, make_profiled_settings):
|
|
# A grid that only holds 0.5 around 25 degC / 50 % (halfway between the
|
|
# 40 % and 60 % columns); every other cell holds 0.1.
|
|
grid = make_grid(0.1)
|
|
grid[ROW_25_DEGC][COLUMN_40_PERCENT] = 0.5
|
|
grid[ROW_25_DEGC][COLUMN_60_PERCENT] = 0.5
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert resolved.temperature_degC == pytest.approx(25.0)
|
|
assert resolved.soc_factor == pytest.approx(0.5)
|
|
assert resolved.max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
def test_explicit_operating_point_is_used(self, make_profiled_settings, measurements):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = 25.0
|
|
cold = settings.resolve_operating_parameters(
|
|
BatteryOperatingPoint(temperature_degC=0.0, soc_factor=0.5)
|
|
)
|
|
assert cold.max_charge_power_w == pytest.approx(1000.0)
|
|
assert cold.temperature_degC == pytest.approx(0.0)
|
|
|
|
|
|
# --- Capacity ------------------------------------------------------------------
|
|
|
|
|
|
class TestCapacityResolution:
|
|
"""Tests for the capacity: profile adjustment > profile, no built-in default."""
|
|
|
|
def test_explicit_capacity_is_used(self):
|
|
assert make_settings(capacity_wh=10000).effective_nominal_capacity_wh == 10000
|
|
|
|
def test_plain_test_profile_capacity(self):
|
|
assert make_settings().effective_nominal_capacity_wh == PROFILE_CAPACITY_WH
|
|
|
|
def test_profile_capacity_is_used_when_not_configured(self, make_profiled_settings):
|
|
profile = make_profile(nominal_capacity_wh=12000.0)
|
|
assert make_profiled_settings(profile).effective_nominal_capacity_wh == 12000
|
|
|
|
def test_adjustment_capacity_replaces_profile_capacity(self, make_profiled_settings):
|
|
profile = make_profile(nominal_capacity_wh=12000.0)
|
|
assert make_profiled_settings(profile, capacity_wh=7000).effective_nominal_capacity_wh == 7000
|
|
|
|
def test_profile_capacity_is_rounded_to_whole_wh(self, make_profiled_settings):
|
|
profile = make_profile(nominal_capacity_wh=9999.6)
|
|
assert make_profiled_settings(profile).effective_nominal_capacity_wh == 10000
|
|
|
|
def test_profile_without_capacity_requires_the_adjustment(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(nominal_capacity_wh=None))
|
|
with pytest.raises(BatteryResolutionError, match="Battery 'battery1'.*generic"):
|
|
settings.resolve_nominal_capacity_wh()
|
|
|
|
def test_resolve_nominal_capacity_wh_matches_computed_field(self, make_profiled_settings):
|
|
profile = make_profile(nominal_capacity_wh=12000.0)
|
|
settings = make_profiled_settings(profile)
|
|
assert settings.resolve_nominal_capacity_wh() == settings.effective_nominal_capacity_wh == 12000
|
|
|
|
def test_power_scales_with_profile_capacity(self, make_profiled_settings):
|
|
profile = make_profile(charge=0.5, nominal_capacity_wh=8000.0)
|
|
resolved = make_profiled_settings(profile).resolve_operating_parameters()
|
|
assert resolved.capacity_wh == 8000
|
|
assert resolved.max_charge_power_w == pytest.approx(4000.0)
|
|
|
|
def test_power_scales_with_adjustment_capacity(self, make_profiled_settings):
|
|
profile = make_profile(charge=0.5, nominal_capacity_wh=8000.0)
|
|
resolved = make_profiled_settings(
|
|
profile, capacity_wh=10000
|
|
).resolve_operating_parameters()
|
|
assert resolved.capacity_wh == 10000
|
|
assert resolved.max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
|
|
# --- Loading the battery profile --------------------------------------------------
|
|
|
|
|
|
class TestGetBatteryProfile:
|
|
"""Tests for lazy loading and caching of the battery profile."""
|
|
|
|
def test_loads_default_profile_by_name(self, install_profile):
|
|
profile = make_profile()
|
|
calls = install_profile(profile)
|
|
settings = make_settings()
|
|
assert settings.get_battery_profile() is profile
|
|
assert calls == ["generic-lfp"]
|
|
|
|
def test_loads_configured_profile_by_name(self, install_profile):
|
|
calls = install_profile(make_profile())
|
|
make_settings(battery_profile="byd-hvs").get_battery_profile()
|
|
assert calls == ["byd-hvs"]
|
|
|
|
def test_loading_is_lazy(self, install_profile):
|
|
calls = install_profile(make_profile())
|
|
make_settings(battery_profile="generic-lfp")
|
|
assert calls == []
|
|
|
|
def test_profile_is_always_taken_from_the_store(self, install_profile):
|
|
# Caching is the job of the profile store (see test_devicesprofilebattery),
|
|
# so a changed profile file is picked up by existing settings instances.
|
|
calls = install_profile(make_profile())
|
|
settings = make_settings(capacity_wh=10000)
|
|
settings.get_battery_profile()
|
|
settings.resolve_operating_parameters()
|
|
_ = settings.effective_nominal_capacity_wh
|
|
_ = settings.effective_max_charge_power_w
|
|
settings.to_genetic_pv_bat_param()
|
|
assert calls == ["generic-lfp"] * 5
|
|
|
|
def test_dump_resolves_the_battery_once(self, install_profile, monkeypatch):
|
|
"""All effective_* fields of one dump share one resolution."""
|
|
from akkudoktoreos.devices.settings import batterysettings
|
|
|
|
install_profile(make_profile())
|
|
settings = make_settings(capacity_wh=10000)
|
|
resolutions: list[int] = []
|
|
original = batterysettings.resolve_battery_parameters
|
|
|
|
def counting(*args, **kwargs):
|
|
resolutions.append(1)
|
|
return original(*args, **kwargs)
|
|
|
|
monkeypatch.setattr(batterysettings, "resolve_battery_parameters", counting)
|
|
dumped = settings.model_dump()
|
|
assert dumped["effective_max_charge_power_w"] is not None
|
|
assert len(resolutions) == 1
|
|
|
|
def test_changed_settings_are_resolved_again(self, install_profile):
|
|
install_profile(make_profile())
|
|
settings = make_settings(capacity_wh=10000)
|
|
before = settings.effective_nominal_capacity_wh
|
|
settings.profile_adjustment.nominal_capacity_wh = 5000
|
|
assert before == 10000
|
|
assert settings.effective_nominal_capacity_wh == 5000
|
|
|
|
@pytest.mark.parametrize(
|
|
("field", "value", "effective", "expected"),
|
|
[
|
|
("min_soc_percentage", 20, "effective_min_soc_percentage", 20),
|
|
("max_soc_percentage", 80, "effective_max_soc_percentage", 80),
|
|
],
|
|
)
|
|
def test_changed_soc_settings_are_resolved_again(
|
|
self, install_profile, field, value, effective, expected
|
|
):
|
|
install_profile(make_profile())
|
|
settings = make_settings(capacity_wh=10000)
|
|
_ = getattr(settings, effective)
|
|
setattr(settings, field, value)
|
|
assert getattr(settings, effective) == expected
|
|
|
|
def test_changed_store_profile_is_used_by_existing_instance(self, install_profile):
|
|
install_profile(make_profile())
|
|
settings = make_settings(capacity_wh=10000)
|
|
before = settings.effective_max_charge_power_w
|
|
assert before is not None
|
|
install_profile(make_profile(charge=0.25))
|
|
assert settings.effective_max_charge_power_w == pytest.approx(before / 2)
|
|
|
|
def test_profile_is_reloaded_when_profile_name_changes(self, install_profile):
|
|
calls = install_profile(make_profile())
|
|
settings = make_settings(battery_profile="profile-a")
|
|
settings.get_battery_profile()
|
|
settings.battery_profile = "profile-b"
|
|
settings.get_battery_profile()
|
|
assert calls == ["profile-a", "profile-b"]
|
|
|
|
def test_missing_profile_error_is_propagated_by_strict_methods(self, broken_profile_loader):
|
|
settings = make_settings(battery_profile="does-not-exist")
|
|
with pytest.raises(FileNotFoundError, match="does-not-exist"):
|
|
settings.get_battery_profile()
|
|
# The resolution names the battery and keeps the cause.
|
|
with pytest.raises(BatteryResolutionError, match="Battery 'battery1'.*does-not-exist"):
|
|
settings.resolve_operating_parameters()
|
|
with pytest.raises(BatteryResolutionError, match="does-not-exist") as raised:
|
|
settings.resolve_nominal_capacity_wh()
|
|
assert isinstance(raised.value.__cause__, FileNotFoundError)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_missing_profile_error_is_propagated_by_conversions(
|
|
self, broken_profile_loader, method
|
|
):
|
|
settings = make_settings(battery_profile="does-not-exist")
|
|
with pytest.raises(BatteryResolutionError, match="does-not-exist"):
|
|
getattr(settings, method)()
|
|
|
|
|
|
# --- Maximum charge power -------------------------------------------------------
|
|
|
|
|
|
class TestMaxChargePower:
|
|
"""Tests for the maximum charge power."""
|
|
|
|
def test_c_rate_limit_is_scaled_by_capacity(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(charge=0.5), capacity_wh=10000)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
def test_profile_power_limit_caps_c_rate_power(self, make_profiled_settings):
|
|
profile = make_profile(charge=0.5, max_charge_power_w=3000.0)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(3000.0)
|
|
|
|
def test_installation_limit_below_profile_limit_wins(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(charge=0.5), capacity_wh=10000, charge_limit_w=2500.0
|
|
)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(2500.0)
|
|
|
|
def test_installation_limit_cannot_exceed_profile_limit(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(charge=0.5), capacity_wh=10000, charge_limit_w=9000.0
|
|
)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
def test_power_unit_is_used_as_is(self, make_profiled_settings):
|
|
profile = make_profile(charge=3000.0, units=Units(limit="W"))
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(3000.0)
|
|
|
|
def test_current_unit_is_converted_with_nominal_voltage(self, make_profiled_settings):
|
|
profile = make_profile(charge=20.0, units=Units(limit="A"), nominal_voltage_v=100.0)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(2000.0)
|
|
|
|
def test_current_unit_without_nominal_voltage_is_rejected(self):
|
|
"""The profile document is rejected, not only its resolution."""
|
|
with pytest.raises(ValueError, match="nominal_voltage_v"):
|
|
make_profile_config(charge=20.0, units=Units(limit="A"))
|
|
|
|
@pytest.mark.parametrize(
|
|
"units", [{"limit": "kW"}, {"limit": "C-rate", "temperature": "degF"},
|
|
{"limit": "C-rate", "soc": "fraction"}],
|
|
)
|
|
def test_unsupported_unit_is_rejected(self, units):
|
|
with pytest.raises(ValueError):
|
|
Units(**units)
|
|
|
|
def test_unsupported_unit_of_a_compiled_profile_raises(self, make_profiled_settings):
|
|
"""Defensive: a compiled profile that bypassed validation fails with a resolution error."""
|
|
profile = dataclasses.replace(make_profile(charge=1.0), limit_unit="kW")
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
with pytest.raises(BatteryResolutionError, match="Unsupported limit unit"):
|
|
settings.resolve_operating_parameters()
|
|
|
|
def test_inhibited_charging_yields_zero_without_raising(self, make_profiled_settings):
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.resolve_operating_parameters().max_charge_power_w == 0.0
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_charging_is_inhibited_at_measured_cold_temperature(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
"""A cold battery may not charge, but the parameters stay valid for the optimization."""
|
|
settings = make_profiled_settings(make_profile(), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = -12.0
|
|
parameters = await current(settings)
|
|
assert parameters.max_charge_power_w == 0.0
|
|
assert settings.to_genetic_pv_bat_param(parameters).max_charge_power_w == 0.0
|
|
assert settings.to_genetic0_pv_bat_param(parameters).max_charge_power_w == 0.0
|
|
|
|
def test_zero_charge_power_yields_zero(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(charge=0.0), capacity_wh=10000)
|
|
assert settings.resolve_operating_parameters().max_charge_power_w == 0.0
|
|
|
|
|
|
# --- Maximum discharge power ----------------------------------------------------
|
|
|
|
|
|
class TestMaxDischargePower:
|
|
"""Tests for the maximum discharge power."""
|
|
|
|
def test_c_rate_limit_is_scaled_by_capacity(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(discharge=0.4), capacity_wh=10000)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(4000.0)
|
|
|
|
def test_profile_power_limit_caps_c_rate_power(self, make_profiled_settings):
|
|
profile = make_profile(discharge=0.4, max_discharge_power_w=2000.0)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(2000.0)
|
|
|
|
def test_installation_limit_below_profile_limit_wins(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(discharge=0.4),
|
|
capacity_wh=10000,
|
|
discharge_limit_w=1500.0,
|
|
)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(1500.0)
|
|
|
|
def test_installation_limit_cannot_exceed_profile_limit(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(discharge=0.4),
|
|
capacity_wh=10000,
|
|
discharge_limit_w=9000.0,
|
|
)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(4000.0)
|
|
|
|
def test_charge_and_discharge_limits_are_independent(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(charge=0.5, discharge=0.2),
|
|
capacity_wh=10000,
|
|
charge_limit_w=1000.0,
|
|
)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(1000.0)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(2000.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_discharge_follows_measured_temperature(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
grid = make_grid(0.4)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(discharge=grid), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = 0.0
|
|
assert (await current(settings)).max_discharge_power_w == pytest.approx(1000.0)
|
|
# The computed field stays at the reference operating point.
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(4000.0)
|
|
|
|
def test_inhibited_discharging_yields_zero_without_raising(self, make_profiled_settings):
|
|
profile = make_profile(hard_cutoffs=discharge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.resolve_operating_parameters().max_discharge_power_w == 0.0
|
|
assert settings.effective_max_discharge_power_w == 0.0
|
|
|
|
def test_inhibited_discharging_does_not_block_conversions(self, make_profiled_settings):
|
|
profile = make_profile(hard_cutoffs=discharge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.to_genetic_pv_bat_param().max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
|
|
# --- Efficiencies ----------------------------------------------------------------
|
|
|
|
|
|
class TestEfficiencyAtMaximumPower:
|
|
"""Tests for efficiencies without a usable power measurement."""
|
|
|
|
def test_charge_efficiency_at_max_charge_power(self, make_profiled_settings, full_profile):
|
|
# 5000 W on 10000 Wh -> 0.5 C -> 0.96
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert settings.effective_charging_efficiency == pytest.approx(0.96)
|
|
|
|
def test_discharge_efficiency_at_max_discharge_power(self, make_profiled_settings, full_profile):
|
|
# 4000 W on 10000 Wh -> 0.4 C -> 0.90 + 0.05 * 0.3 / 0.4 = 0.9375
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert settings.effective_discharging_efficiency == pytest.approx(0.9375)
|
|
|
|
def test_installation_limit_changes_c_rate(self, make_profiled_settings):
|
|
# Charge capped to 2500 W -> 0.25 C -> 0.90 + 0.06 * 0.15 / 0.4 = 0.9225
|
|
profile = make_profile(charge_efficiency=make_curve([0.1, 0.5, 1.0], [0.90, 0.96, 0.92]))
|
|
settings = make_profiled_settings(
|
|
profile, capacity_wh=10000, charge_limit_w=2500.0
|
|
)
|
|
assert settings.effective_charging_efficiency == pytest.approx(0.9225)
|
|
|
|
def test_profile_power_limit_changes_c_rate(self, make_profiled_settings):
|
|
# Discharge capped to 2000 W -> 0.2 C -> 0.90 + 0.05 * 0.1 / 0.4 = 0.9125
|
|
profile = make_profile(
|
|
discharge_efficiency=make_curve([0.1, 0.5], [0.90, 0.95]),
|
|
max_discharge_power_w=2000.0,
|
|
)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
def test_efficiency_depends_on_c_rate_not_on_capacity(
|
|
self, make_profiled_settings, full_profile
|
|
):
|
|
# Same 0.5 C limit on a smaller capacity: lower power, same C-rate.
|
|
settings = make_profiled_settings(full_profile, capacity_wh=5000)
|
|
assert settings.effective_max_charge_power_w == pytest.approx(2500.0)
|
|
assert settings.effective_charging_efficiency == pytest.approx(0.96)
|
|
|
|
def test_flat_curves_give_their_efficiency(self):
|
|
settings = make_settings(capacity_wh=10000)
|
|
assert settings.effective_charging_efficiency == pytest.approx(PROFILE_EFFICIENCY)
|
|
assert settings.effective_discharging_efficiency == pytest.approx(PROFILE_EFFICIENCY)
|
|
|
|
def test_inhibited_discharging_uses_efficiency_at_lowest_c_rate(self, make_profiled_settings):
|
|
profile = make_profile(
|
|
discharge_efficiency=make_curve([0.1, 0.5], [0.90, 0.95]),
|
|
hard_cutoffs=discharge_inhibited_below_30(),
|
|
)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(0.0)
|
|
assert settings.effective_discharging_efficiency == pytest.approx(0.90)
|
|
|
|
def test_rejected_c_rate_uses_nearest_curve_breakpoint(self, make_profiled_settings):
|
|
curve = EfficiencyCurve(
|
|
c_rate=[0.1, 1.0],
|
|
efficiency=[0.90, 0.92],
|
|
out_of_range_behavior=OutOfRangeBehavior.REJECT,
|
|
)
|
|
# 1.5 C is beyond the curve, which rejects it.
|
|
profile = make_profile(charge=1.5, charge_efficiency=curve)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert settings.effective_charging_efficiency == pytest.approx(0.92)
|
|
|
|
|
|
class TestEfficiencyAtMeasuredPower:
|
|
"""Tests for efficiencies taken at the measured charge / discharge power."""
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_charge_efficiency_at_measured_charge_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
# 2500 W -> 0.25 C -> 0.9225 (maximum power would give 0.96)
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.9225)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_discharge_efficiency_at_measured_discharge_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
# 2000 W -> 0.2 C -> 0.9125 (maximum power would give 0.9375)
|
|
measurements["battery1-discharge-power-w"] = 2000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_directions_are_independent(self, make_profiled_settings, full_profile, measurements):
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.9225)
|
|
assert (await current(settings)).discharging_efficiency == pytest.approx(0.9375)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_power_scales_with_capacity(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
# 2500 W on 5000 Wh is 0.5 C -> 0.96
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=5000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.96)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_negative_measurement_is_used_as_magnitude(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
measurements["battery1-discharge-power-w"] = -2000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_zero_measurement_falls_back_to_maximum_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
measurements["battery1-charge-power-w"] = 0.0
|
|
measurements["battery1-discharge-power-w"] = 0.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.96)
|
|
assert (await current(settings)).discharging_efficiency == pytest.approx(0.9375)
|
|
|
|
@pytest.mark.parametrize("measured", [float("nan"), float("inf")])
|
|
@pytest.mark.asyncio
|
|
async def test_non_finite_measurement_falls_back_to_maximum_power(
|
|
self, make_profiled_settings, full_profile, measurements, measured
|
|
):
|
|
measurements["battery1-charge-power-w"] = measured
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.96)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measurement_beyond_curve_is_clamped_by_profile(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
# 20000 W -> 2 C is beyond the curve, clamped to the last point 0.92.
|
|
measurements["battery1-charge-power-w"] = 20000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.92)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_power_is_not_limited_by_maximum_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
# Installation limit 1000 W, measured 5000 W (0.5 C): measurement wins.
|
|
measurements["battery1-charge-power-w"] = 5000.0
|
|
settings = make_profiled_settings(
|
|
full_profile, capacity_wh=10000, charge_limit_w=1000.0
|
|
)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(0.96)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_discharge_power_used_while_discharging_is_inhibited(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
profile = make_profile(
|
|
discharge_efficiency=make_curve([0.1, 0.5], [0.90, 0.95]),
|
|
hard_cutoffs=discharge_inhibited_below_30(),
|
|
)
|
|
measurements["battery1-discharge-power-w"] = 2000.0
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert (await current(settings)).discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_power_on_flat_curve_gives_its_efficiency(
|
|
self, make_profiled_settings, measurements
|
|
):
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
settings = make_profiled_settings(make_profile(), capacity_wh=10000)
|
|
assert (await current(settings)).charging_efficiency == pytest.approx(PROFILE_EFFICIENCY)
|
|
|
|
def test_explicit_powers_are_used(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
measurements["battery1-charge-power-w"] = 5000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
resolved = settings.resolve_operating_parameters(
|
|
BatteryOperatingPoint(charge_power_w=2500.0, discharge_power_w=2000.0)
|
|
)
|
|
assert resolved.charging_efficiency == pytest.approx(0.9225)
|
|
assert resolved.discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_power_does_not_change_maximum_power(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
measurements["battery1-discharge-power-w"] = 2000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
assert (await current(settings)).max_charge_power_w == pytest.approx(5000.0)
|
|
assert (await current(settings)).max_discharge_power_w == pytest.approx(4000.0)
|
|
|
|
|
|
# --- SoC range -----------------------------------------------------------------
|
|
|
|
|
|
class TestSocRangeResolution:
|
|
"""Tests that the user's SoC range is clamped into the technical bounds."""
|
|
|
|
def test_technical_bounds_apply_to_default_range(self, make_profiled_settings):
|
|
profile = make_profile(technical_min_soc_percent=5.0, technical_max_soc_percent=95.0)
|
|
resolved = make_profiled_settings(profile).resolve_operating_parameters()
|
|
assert resolved.min_soc_percentage == 5
|
|
assert resolved.max_soc_percentage == 95
|
|
|
|
def test_technical_bounds_are_rounded_inwards(self, make_profiled_settings):
|
|
profile = make_profile(technical_min_soc_percent=4.2, technical_max_soc_percent=95.8)
|
|
resolved = make_profiled_settings(profile).resolve_operating_parameters()
|
|
assert resolved.min_soc_percentage == 5
|
|
assert resolved.max_soc_percentage == 95
|
|
|
|
def test_stricter_user_range_is_kept(self, make_profiled_settings):
|
|
profile = make_profile(technical_min_soc_percent=5.0, technical_max_soc_percent=95.0)
|
|
settings = make_profiled_settings(profile, min_soc_percentage=10, max_soc_percentage=90)
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert resolved.min_soc_percentage == 10
|
|
assert resolved.max_soc_percentage == 90
|
|
|
|
def test_profile_without_bounds_keeps_user_range(self, make_profiled_settings):
|
|
settings = make_profiled_settings(
|
|
make_profile(), min_soc_percentage=10, max_soc_percentage=90
|
|
)
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert resolved.min_soc_percentage == 10
|
|
assert resolved.max_soc_percentage == 90
|
|
|
|
def test_empty_range_after_clamping_raises(self, make_profiled_settings):
|
|
profile = make_profile(technical_min_soc_percent=60.0)
|
|
settings = make_profiled_settings(profile, max_soc_percentage=50)
|
|
with pytest.raises(ValueError, match="empty"):
|
|
settings.resolve_operating_parameters()
|
|
|
|
def test_effective_soc_fields_use_technical_bounds(self, make_profiled_settings):
|
|
profile = make_profile(technical_min_soc_percent=5.0, technical_max_soc_percent=95.0)
|
|
settings = make_profiled_settings(profile)
|
|
assert settings.effective_min_soc_percentage == 5
|
|
assert settings.effective_max_soc_percentage == 95
|
|
|
|
|
|
# --- Strict resolution -----------------------------------------------------------
|
|
|
|
|
|
class TestResolveOperatingParameters:
|
|
"""Tests for the consistent strict snapshot."""
|
|
|
|
def test_snapshot_contains_all_values(self, make_profiled_settings, full_profile):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
resolved = settings.resolve_operating_parameters()
|
|
assert isinstance(resolved, BatteryOperatingParameters)
|
|
values = dataclasses.asdict(resolved)
|
|
# The snapshot brings the profile it was resolved from (see the conversion tests).
|
|
assert values.pop("profile") is not None
|
|
assert values == pytest.approx(
|
|
{
|
|
"temperature_degC": 25.0,
|
|
"soc_factor": 0.5,
|
|
"capacity_wh": 10000,
|
|
"charging_efficiency": 0.96,
|
|
"discharging_efficiency": 0.9375,
|
|
"max_charge_power_w": 5000.0,
|
|
"max_discharge_power_w": 4000.0,
|
|
"min_soc_percentage": 5,
|
|
"max_soc_percentage": 95,
|
|
}
|
|
)
|
|
|
|
def test_snapshot_is_immutable(self):
|
|
resolved = make_settings().resolve_operating_parameters()
|
|
with pytest.raises((AttributeError, TypeError)):
|
|
resolved.capacity_wh = 1 # type: ignore[misc]
|
|
|
|
def test_snapshot_is_not_affected_by_later_measurement_changes(
|
|
self, make_profiled_settings, full_profile, measurements
|
|
):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
resolved = settings.resolve_operating_parameters()
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
assert resolved.charging_efficiency == pytest.approx(0.96)
|
|
|
|
|
|
# --- Optimization parameters ---------------------------------------------------
|
|
|
|
|
|
class TestOptimizationParameters:
|
|
"""Tests that the conversions use the battery profile at the operating point."""
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_values_come_from_profile(self, make_profiled_settings, full_profile, method):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
params = getattr(settings, method)()
|
|
assert params.device_id == "battery1"
|
|
assert params.capacity_wh == 10000
|
|
assert params.max_charge_power_w == pytest.approx(5000.0)
|
|
assert params.charging_efficiency == pytest.approx(0.96)
|
|
assert params.discharging_efficiency == pytest.approx(0.9375)
|
|
assert params.min_soc_percentage == 5
|
|
assert params.max_soc_percentage == 95
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_parameters_match_computed_fields(self, make_profiled_settings, full_profile, method):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
params = getattr(settings, method)()
|
|
assert params.capacity_wh == settings.effective_nominal_capacity_wh
|
|
assert params.charging_efficiency == pytest.approx(settings.effective_charging_efficiency)
|
|
assert params.discharging_efficiency == pytest.approx(settings.effective_discharging_efficiency)
|
|
assert params.max_charge_power_w == pytest.approx(settings.effective_max_charge_power_w)
|
|
assert params.min_soc_percentage == settings.effective_min_soc_percentage
|
|
assert params.max_soc_percentage == settings.effective_max_soc_percentage
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
@pytest.mark.asyncio
|
|
async def test_parameters_use_measured_operating_point(
|
|
self, make_profiled_settings, measurements, method
|
|
):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
measurements["battery1-temperature-degc"] = 0.0
|
|
params = getattr(settings, method)(await current(settings))
|
|
assert params.max_charge_power_w == pytest.approx(1000.0)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
@pytest.mark.asyncio
|
|
async def test_parameters_use_measured_power_for_efficiency(
|
|
self, make_profiled_settings, full_profile, measurements, method
|
|
):
|
|
measurements["battery1-charge-power-w"] = 2500.0
|
|
measurements["battery1-discharge-power-w"] = 2000.0
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
params = getattr(settings, method)(await current(settings))
|
|
assert params.charging_efficiency == pytest.approx(0.9225)
|
|
assert params.discharging_efficiency == pytest.approx(0.9125)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_without_snapshot_reference_point_is_used(
|
|
self, make_profiled_settings, measurement_calls, method
|
|
):
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
assert getattr(settings, method)().max_charge_power_w == pytest.approx(5000.0)
|
|
assert measurement_calls == []
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_snapshot_is_converted_as_given(self, make_profiled_settings, full_profile, method):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
snapshot = settings.resolve_operating_parameters(
|
|
BatteryOperatingPoint(charge_power_w=2500.0)
|
|
)
|
|
params = getattr(settings, method)(snapshot)
|
|
assert params.capacity_wh == snapshot.capacity_wh
|
|
assert params.charging_efficiency == pytest.approx(snapshot.charging_efficiency)
|
|
assert params.max_charge_power_w == pytest.approx(snapshot.max_charge_power_w)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_capacity_comes_from_profile_when_not_configured(
|
|
self, make_profiled_settings, method
|
|
):
|
|
profile = make_profile(charge=0.5, nominal_capacity_wh=8000.0)
|
|
params = getattr(make_profiled_settings(profile), method)()
|
|
assert params.capacity_wh == 8000
|
|
assert params.max_charge_power_w == pytest.approx(4000.0)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_installation_limit_is_applied(self, make_profiled_settings, full_profile, method):
|
|
settings = make_profiled_settings(
|
|
full_profile, capacity_wh=10000, charge_limit_w=2000.0
|
|
)
|
|
assert getattr(settings, method)().max_charge_power_w == pytest.approx(2000.0)
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_user_soc_range_is_clamped_into_technical_bounds(
|
|
self, make_profiled_settings, full_profile, method
|
|
):
|
|
settings = make_profiled_settings(
|
|
full_profile, capacity_wh=10000, min_soc_percentage=10, max_soc_percentage=90
|
|
)
|
|
params = getattr(settings, method)()
|
|
assert params.min_soc_percentage == 10
|
|
assert params.max_soc_percentage == 90
|
|
|
|
@pytest.mark.parametrize("method", PARAMETER_METHODS)
|
|
def test_inhibited_charging_gives_valid_parameters(self, make_profiled_settings, method):
|
|
"""The optimization gets valid parameters that do not allow charging."""
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
assert getattr(settings, method)().max_charge_power_w == 0.0
|
|
|
|
def test_genetic_pv_receives_storage_cost(self):
|
|
params = make_settings(levelized_cost_of_storage_amt_kwh=0.12).to_genetic_pv_bat_param()
|
|
assert params.levelized_cost_of_storage_kwh == pytest.approx(0.12)
|
|
|
|
def test_genetic_ev_receives_soc_deadline_settings(self):
|
|
params = make_settings(min_soc_max_duration_h=6.0).to_genetic_ev_bat_param()
|
|
assert params.min_soc_max_duration_h == pytest.approx(6.0)
|
|
assert params.min_soc_deadline_datetime is None
|
|
|
|
|
|
# --- Real measurement store ------------------------------------------------------
|
|
|
|
|
|
class TestMeasurementAccess:
|
|
"""Tests that the operating point is read from the real measurement store.
|
|
|
|
These tests use the real (async) accessor, so a missing ``await`` on
|
|
``DataSequence.key_to_value`` surfaces here and not only in production.
|
|
"""
|
|
|
|
@pytest.fixture(autouse=True)
|
|
def _real_measurement_access(self, monkeypatch: pytest.MonkeyPatch, config_eos):
|
|
from akkudoktoreos.core.coreabc import get_measurement
|
|
|
|
monkeypatch.setattr(batterymeasurement, "get_measured_value", REAL_GET_MEASURED_VALUE)
|
|
config_eos.merge_settings_from_dict(
|
|
{"devices": {"batteries": {"battery1": {"device_id": "battery1"}}}}
|
|
)
|
|
get_measurement()._db_reset_state()
|
|
yield
|
|
get_measurement()._db_reset_state()
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measured_values_are_read(self):
|
|
from akkudoktoreos.core.coreabc import get_measurement
|
|
from akkudoktoreos.utils.datetimeutil import to_datetime
|
|
|
|
now = to_datetime()
|
|
await get_measurement().update_value(
|
|
now,
|
|
{
|
|
"battery1-soc-factor": 0.35,
|
|
"battery1-temperature-degc": 12.5,
|
|
"battery1-charge-power-w": 2500.0,
|
|
},
|
|
)
|
|
point = await make_settings().measure_operating_point(now)
|
|
assert point.soc_factor == pytest.approx(0.35)
|
|
assert point.temperature_degC == pytest.approx(12.5)
|
|
assert point.charge_power_w == pytest.approx(2500.0)
|
|
assert point.discharge_power_w is None
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_empty_store_yields_reference_point(self):
|
|
point = await make_settings().measure_operating_point()
|
|
assert point == BatteryOperatingPoint()
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_measurement_outside_age_window_is_ignored(self):
|
|
from akkudoktoreos.core.coreabc import get_measurement
|
|
from akkudoktoreos.utils.datetimeutil import to_datetime
|
|
|
|
now = to_datetime()
|
|
await get_measurement().update_value(
|
|
now.subtract(hours=3), {"battery1-soc-factor": 0.9}
|
|
)
|
|
point = await make_settings().measure_operating_point(now)
|
|
assert point.soc_factor == pytest.approx(BATTERY_DEFAULT_SOC_FACTOR)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_current_resolution_uses_real_measurements(self, make_profiled_settings):
|
|
from akkudoktoreos.core.coreabc import get_measurement
|
|
from akkudoktoreos.utils.datetimeutil import to_datetime
|
|
|
|
grid = make_grid(0.5)
|
|
grid[ROW_0_DEGC] = [0.1] * 10
|
|
settings = make_profiled_settings(make_profile(charge=grid), capacity_wh=10000)
|
|
now = to_datetime()
|
|
await get_measurement().update_value(now, {"battery1-temperature-degc": 0.0})
|
|
resolved = await settings.resolve_current_operating_parameters(now)
|
|
assert resolved.max_charge_power_w == pytest.approx(1000.0)
|
|
|
|
|
|
class TestGeneticPowerCurves:
|
|
"""The GENETIC parameters carry the profile as SoC tables and efficiency curves."""
|
|
|
|
# SoC axis [0, 5, 10, 20, 40, 60, 80, 90, 95, 100]: full 1.0 C up to 80 %,
|
|
# then tapering to 0.5 C at 100 %.
|
|
TAPER = [1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 1.0, 0.8, 0.6, 0.5]
|
|
# Temperature axis [-10, -5, 0, 5, 10, 15, 25, 35, 45, 50]: 0.2 C at 10 degC,
|
|
# 0.5 C at 25 degC.
|
|
BY_TEMPERATURE = [0.1, 0.1, 0.1, 0.15, 0.2, 0.3, 0.5, 0.5, 0.5, 0.5]
|
|
|
|
@staticmethod
|
|
def snapshot(temperature_degC: float = 25.0) -> BatteryOperatingParameters:
|
|
"""Return a resolved snapshot that does not depend on a profile."""
|
|
return BatteryOperatingParameters(
|
|
temperature_degC=temperature_degC,
|
|
soc_factor=0.5,
|
|
capacity_wh=10000,
|
|
charging_efficiency=0.9,
|
|
discharging_efficiency=0.9,
|
|
max_charge_power_w=3000.0,
|
|
max_discharge_power_w=2000.0,
|
|
min_soc_percentage=0,
|
|
max_soc_percentage=100,
|
|
)
|
|
|
|
@pytest.mark.parametrize("converter", ["to_genetic_pv_bat_param", "to_genetic_ev_bat_param"])
|
|
def test_tables_follow_soc(self, make_profiled_settings, converter):
|
|
profile = make_profile(charge=[list(self.TAPER) for _ in range(10)], discharge=0.4)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
parameters = getattr(settings, converter)()
|
|
|
|
charge = parameters.charge_power_limit_w_by_soc
|
|
discharge = parameters.discharge_power_limit_w_by_soc
|
|
assert charge is not None and len(charge) == 101
|
|
assert discharge is not None and len(discharge) == 101
|
|
assert charge[50] == pytest.approx(10000.0)
|
|
assert charge[80] == pytest.approx(10000.0)
|
|
assert charge[90] == pytest.approx(8000.0)
|
|
assert charge[100] == pytest.approx(5000.0)
|
|
assert all(a >= b for a, b in zip(charge[80:], charge[81:]))
|
|
assert discharge == pytest.approx([4000.0] * 101)
|
|
assert parameters.max_charge_power_w == pytest.approx(10000.0)
|
|
assert parameters.max_discharge_power_w == pytest.approx(4000.0)
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_rated_power_is_the_peak_over_soc(self, make_profiled_settings, measurements):
|
|
"""At a high measured SoC the snapshot is tapered, the rated power is not."""
|
|
profile = make_profile(charge=[list(self.TAPER) for _ in range(10)], discharge=0.4)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
measurements["battery1-soc-factor"] = 1.0
|
|
snapshot = await current(settings)
|
|
assert snapshot.max_charge_power_w == pytest.approx(5000.0)
|
|
|
|
parameters = settings.to_genetic_pv_bat_param(snapshot)
|
|
assert parameters.max_charge_power_w == pytest.approx(10000.0)
|
|
assert parameters.charge_power_limit_w_by_soc[100] == pytest.approx(5000.0)
|
|
|
|
@pytest.mark.asyncio
|
|
@pytest.mark.parametrize(
|
|
"temperature, expected_w",
|
|
[(10.0, 2000.0), (None, 5000.0)], # None: no measurement, 25 degC assumed
|
|
)
|
|
async def test_tables_at_measured_temperature(
|
|
self, make_profiled_settings, measurements, temperature, expected_w
|
|
):
|
|
grid = [[value] * 10 for value in self.BY_TEMPERATURE]
|
|
settings = make_profiled_settings(
|
|
make_profile(charge=grid, discharge=grid), capacity_wh=10000
|
|
)
|
|
if temperature is not None:
|
|
measurements["battery1-temperature-degc"] = temperature
|
|
|
|
parameters = settings.to_genetic_pv_bat_param(await current(settings))
|
|
assert parameters.charge_power_limit_w_by_soc == pytest.approx([expected_w] * 101)
|
|
assert parameters.discharge_power_limit_w_by_soc == pytest.approx([expected_w] * 101)
|
|
|
|
def test_installation_limits_cap_tables(self, make_profiled_settings):
|
|
profile = make_profile(charge=[list(self.TAPER) for _ in range(10)], discharge=0.4)
|
|
settings = make_profiled_settings(
|
|
profile,
|
|
capacity_wh=10000,
|
|
charge_limit_w=6000,
|
|
discharge_limit_w=1000,
|
|
)
|
|
parameters = settings.to_genetic_pv_bat_param()
|
|
assert max(parameters.charge_power_limit_w_by_soc) == pytest.approx(6000.0)
|
|
assert parameters.charge_power_limit_w_by_soc[100] == pytest.approx(5000.0)
|
|
assert parameters.discharge_power_limit_w_by_soc == pytest.approx([1000.0] * 101)
|
|
assert parameters.max_charge_power_w == pytest.approx(6000.0)
|
|
assert parameters.max_discharge_power_w == pytest.approx(1000.0)
|
|
|
|
def test_efficiency_curves_over_power_fraction(self, make_profiled_settings, full_profile):
|
|
settings = make_profiled_settings(full_profile, capacity_wh=10000)
|
|
parameters = settings.to_genetic_pv_bat_param()
|
|
|
|
charging = parameters.charging_efficiency_curve
|
|
discharging = parameters.discharging_efficiency_curve
|
|
assert charging is not None and discharging is not None
|
|
assert [point[0] for point in charging] == pytest.approx([i / 20 for i in range(21)])
|
|
# Rated charge power 0.5 C: fraction 1.0 is 0.5 C, fraction 0.2 is 0.1 C.
|
|
assert charging[-1][1] == pytest.approx(0.96)
|
|
assert charging[4][1] == pytest.approx(0.90)
|
|
# Rated discharge power 0.4 C: between 0.90 at 0.1 C and 0.95 at 0.5 C.
|
|
assert discharging[-1][1] == pytest.approx(0.9375)
|
|
|
|
def test_efficiency_curves_come_from_the_profile(self):
|
|
parameters = make_settings(capacity_wh=10000).to_genetic_pv_bat_param()
|
|
assert parameters.charge_power_limit_w_by_soc is not None
|
|
assert parameters.charging_efficiency_curve is not None
|
|
assert parameters.discharging_efficiency_curve is not None
|
|
assert {e for _, e in parameters.charging_efficiency_curve} == {PROFILE_EFFICIENCY}
|
|
|
|
def test_no_tables_if_charging_is_inhibited_at_every_soc(self, make_profiled_settings):
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
snapshot = self.snapshot(temperature_degC=20.0)
|
|
assert settings.resolve_power_curves(snapshot) is None
|
|
|
|
parameters = settings.to_genetic_pv_bat_param(snapshot)
|
|
assert parameters.charge_power_limit_w_by_soc is None
|
|
assert parameters.max_charge_power_w == pytest.approx(snapshot.max_charge_power_w)
|
|
|
|
def test_snapshot_without_profile_converts_without_tables(self, broken_profile_loader):
|
|
"""A snapshot resolved without profile is converted as is: no load, no abort."""
|
|
snapshot = self.snapshot()
|
|
settings = make_settings(battery_profile="does-not-exist")
|
|
converted = settings.to_genetic_pv_bat_param(snapshot)
|
|
assert converted.max_charge_power_w == snapshot.max_charge_power_w
|
|
assert converted.max_discharge_power_w == snapshot.max_discharge_power_w
|
|
assert converted.charge_power_limit_w_by_soc is None
|
|
|
|
|
|
# --- Profile check ---------------------------------------------------------------
|
|
|
|
|
|
class TestProfileCheck:
|
|
"""Tests for check_profile, which reports problems instead of raising."""
|
|
|
|
def test_resolvable_battery_has_no_problems(self):
|
|
assert make_settings(capacity_wh=10000).check_profile() == ([], [])
|
|
|
|
def test_missing_profile_is_an_error(self, broken_profile_loader):
|
|
errors, warnings = make_settings(battery_profile="does-not-exist").check_profile()
|
|
assert len(errors) == 1
|
|
assert "Battery 'battery1'" in errors[0]
|
|
assert "does-not-exist" in errors[0]
|
|
assert warnings == []
|
|
|
|
def test_generic_profile_without_capacity_is_an_error(self, make_profiled_settings):
|
|
settings = make_profiled_settings(make_profile(nominal_capacity_wh=None))
|
|
errors, _ = settings.check_profile()
|
|
assert len(errors) == 1
|
|
assert "profile_adjustment.nominal_capacity_wh" in errors[0]
|
|
|
|
def test_power_limit_above_profile_is_a_warning(self):
|
|
# The plain profile allows 0.5 C of 10 kWh = 5 kW charging, 0.4 C = 4 kW discharging.
|
|
settings = make_settings(capacity_wh=10000, charge_limit_w=6000.0, discharge_limit_w=3000.0)
|
|
errors, warnings = settings.check_profile()
|
|
assert errors == []
|
|
assert len(warnings) == 1
|
|
assert "profile_adjustment.max_charge_power_w" in warnings[0]
|
|
# The profile value applies.
|
|
assert settings.effective_max_charge_power_w == pytest.approx(5000.0)
|
|
assert settings.effective_max_discharge_power_w == pytest.approx(3000.0)
|
|
|
|
def test_power_limit_below_profile_is_no_warning(self):
|
|
settings = make_settings(capacity_wh=10000, charge_limit_w=2000.0)
|
|
assert settings.check_profile() == ([], [])
|
|
|
|
def test_no_charging_at_the_reference_point_is_an_error(self, make_profiled_settings):
|
|
"""A profile that cannot charge at the reference temperature is a configuration error."""
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
errors, _ = make_profiled_settings(profile, capacity_wh=10000).check_profile()
|
|
assert len(errors) == 1
|
|
assert "allows no charging at the reference operating point" in errors[0]
|
|
|
|
|
|
# --- Defaults for the optimization ------------------------------------------------
|
|
|
|
|
|
@pytest.fixture
|
|
def logged_errors():
|
|
"""Collect the messages logged at ERROR level."""
|
|
from loguru import logger
|
|
|
|
messages: list[str] = []
|
|
sink_id = logger.add(lambda message: messages.append(message.record["message"]), level="ERROR")
|
|
yield messages
|
|
logger.remove(sink_id)
|
|
|
|
|
|
class TestOptimizationDefaults:
|
|
"""resolve_operating_parameters_or_defaults never fails for a configuration error."""
|
|
|
|
def test_resolvable_battery_matches_strict_resolution(self, logged_errors):
|
|
settings = make_settings(capacity_wh=10000)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert parameters == settings.resolve_operating_parameters()
|
|
assert use_tables is True
|
|
assert logged_errors == []
|
|
|
|
def test_missing_profile_uses_adjustment_and_former_defaults(
|
|
self, broken_profile_loader, logged_errors
|
|
):
|
|
settings = make_settings(battery_profile="does-not-exist", charge_limit_w=3000.0)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is False
|
|
assert parameters.capacity_wh == 8000
|
|
# The adjustment applies where set.
|
|
assert parameters.max_charge_power_w == pytest.approx(3000.0)
|
|
assert parameters.max_discharge_power_w == pytest.approx(5000.0)
|
|
assert parameters.charging_efficiency == pytest.approx(0.88)
|
|
assert parameters.discharging_efficiency == pytest.approx(0.88)
|
|
assert len(logged_errors) == 1
|
|
message = logged_errors[0]
|
|
assert "Battery 'battery1'" in message and "does-not-exist" in message
|
|
assert "nominal capacity 8000 Wh" in message
|
|
assert "maximum discharge power 5000.0 W" in message
|
|
# Not a default: the configured charge limit.
|
|
assert "maximum charge power" not in message
|
|
|
|
def test_unusable_profile_uses_the_generic_profile(self, monkeypatch, logged_errors):
|
|
generic = make_profile(nominal_capacity_wh=None)
|
|
requested: list[str] = []
|
|
|
|
def get(document_type, name, **options):
|
|
requested.append(name)
|
|
if name == BATTERY_DEFAULT_PROFILE:
|
|
return generic
|
|
raise FileNotFoundError(f"No battery profile for '{name}'")
|
|
|
|
monkeypatch.setattr(get_profile_store(), "get", get)
|
|
settings = make_settings(battery_profile="does-not-exist", capacity_wh=10000)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert requested == ["does-not-exist", BATTERY_DEFAULT_PROFILE]
|
|
# The generic profile applies: its tables and 0.5 C of the configured capacity.
|
|
assert use_tables is True
|
|
assert parameters.profile is generic
|
|
assert parameters.capacity_wh == 10000
|
|
assert parameters.max_charge_power_w == pytest.approx(5000.0)
|
|
assert len(logged_errors) == 1
|
|
assert "does-not-exist" in logged_errors[0]
|
|
assert logged_errors[0].endswith(
|
|
f"Using defaults for the optimization: battery profile '{BATTERY_DEFAULT_PROFILE}'."
|
|
)
|
|
|
|
def test_unusable_generic_profile_uses_the_former_defaults(
|
|
self, broken_profile_loader, logged_errors
|
|
):
|
|
settings = make_settings(battery_profile=BATTERY_DEFAULT_PROFILE)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is False
|
|
assert parameters.charging_efficiency == pytest.approx(0.88)
|
|
assert len(logged_errors) == 1
|
|
assert f"battery profile '{BATTERY_DEFAULT_PROFILE}'" not in logged_errors[0].split(
|
|
"Using defaults"
|
|
)[1]
|
|
|
|
def test_generic_profile_without_capacity_uses_default_capacity_only(
|
|
self, make_profiled_settings, logged_errors
|
|
):
|
|
settings = make_profiled_settings(make_profile(nominal_capacity_wh=None))
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is True
|
|
assert parameters.capacity_wh == 8000
|
|
# The profile still applies: 0.5 C of the default capacity.
|
|
assert parameters.max_charge_power_w == pytest.approx(4000.0)
|
|
assert len(logged_errors) == 1
|
|
assert "profile_adjustment.nominal_capacity_wh" in logged_errors[0]
|
|
assert logged_errors[0].endswith("Using defaults for the optimization: nominal capacity 8000 Wh.")
|
|
|
|
def test_soc_range_outside_technical_bounds_uses_technical_range(
|
|
self, make_profiled_settings, logged_errors
|
|
):
|
|
profile = make_profile(technical_min_soc_percent=5.0, technical_max_soc_percent=90.0)
|
|
settings = make_profiled_settings(
|
|
profile, capacity_wh=10000, min_soc_percentage=95, max_soc_percentage=100
|
|
)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is True
|
|
assert (parameters.min_soc_percentage, parameters.max_soc_percentage) == (5, 90)
|
|
assert len(logged_errors) == 1
|
|
assert "SoC range 5 ... 90 %" in logged_errors[0]
|
|
|
|
def test_unconvertible_discharge_limit_gives_defaults(
|
|
self, make_profiled_settings, logged_errors
|
|
):
|
|
"""With charging inhibited, a discharge limit that cannot be converted is still reported.
|
|
|
|
Current limits without nominal voltage cannot be converted to power. The
|
|
optimization gets the defaults instead of an exception.
|
|
"""
|
|
# Only a compiled profile that bypassed validation can miss the voltage.
|
|
profile = dataclasses.replace(
|
|
make_profile(
|
|
charge=20.0,
|
|
discharge=20.0,
|
|
units=Units(limit="A"),
|
|
nominal_voltage_v=100.0,
|
|
hard_cutoffs=charge_inhibited_below_30(),
|
|
),
|
|
nominal_voltage_v=None,
|
|
)
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is False
|
|
assert parameters.max_discharge_power_w > 0
|
|
assert len(logged_errors) == 1
|
|
assert "nominal_voltage_v" in logged_errors[0]
|
|
|
|
@pytest.mark.parametrize("method", ["to_genetic_pv_bat_param", "to_genetic_ev_bat_param"])
|
|
def test_conversion_uses_the_profile_of_the_snapshot(self, monkeypatch, method):
|
|
"""A profile deleted between resolution and conversion does not abort the run."""
|
|
settings = make_settings(capacity_wh=10000)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is True
|
|
expected = getattr(settings, method)(parameters, use_tables)
|
|
|
|
def missing(document_type, name, **options):
|
|
raise FileNotFoundError(f"No battery profile for '{name}'")
|
|
|
|
monkeypatch.setattr(get_profile_store(), "get", missing)
|
|
converted = getattr(settings, method)(parameters, use_tables)
|
|
assert converted.model_dump() == expected.model_dump()
|
|
|
|
def test_inhibited_charging_is_no_configuration_error(
|
|
self, make_profiled_settings, logged_errors
|
|
):
|
|
"""Inhibited charging gives valid parameters with 0 W charge power and no error."""
|
|
profile = make_profile(hard_cutoffs=charge_inhibited_below_30())
|
|
settings = make_profiled_settings(profile, capacity_wh=10000)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is True
|
|
assert parameters.max_charge_power_w == 0.0
|
|
assert logged_errors == []
|
|
|
|
@pytest.mark.parametrize("error", [PermissionError, IsADirectoryError])
|
|
def test_unreadable_profile_uses_adjustment(self, monkeypatch, logged_errors, error):
|
|
def unreadable(document_type, name, **options):
|
|
raise error(f"Battery profile '{name}' is not readable")
|
|
|
|
monkeypatch.setattr(get_profile_store(), "get", unreadable)
|
|
settings = make_settings(charge_limit_w=3000.0)
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults()
|
|
assert use_tables is False
|
|
assert parameters.max_charge_power_w == pytest.approx(3000.0)
|
|
assert len(logged_errors) == 1
|
|
assert "is not readable" in logged_errors[0]
|
|
|
|
def test_report_false_logs_nothing(self, broken_profile_loader, logged_errors):
|
|
make_settings().resolve_operating_parameters_or_defaults(report=False)
|
|
assert logged_errors == []
|
|
|
|
@pytest.mark.parametrize("method", ["to_genetic_pv_bat_param", "to_genetic_ev_bat_param"])
|
|
def test_conversion_without_profile_tables(self, broken_profile_loader, method):
|
|
settings = make_settings(battery_profile="does-not-exist")
|
|
parameters, use_tables = settings.resolve_operating_parameters_or_defaults(report=False)
|
|
converted = getattr(settings, method)(parameters, use_tables)
|
|
assert converted.capacity_wh == 8000
|
|
assert converted.max_charge_power_w == pytest.approx(5000.0)
|
|
assert converted.charge_power_limit_w_by_soc is None
|
|
assert converted.charging_efficiency_curve is None
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_current_operating_point_variant(self, broken_profile_loader, measurements):
|
|
measurements["battery1-temperature-degc"] = 10.0
|
|
settings = make_settings()
|
|
parameters, use_tables = await settings.resolve_current_operating_parameters_or_defaults(
|
|
report=False
|
|
)
|
|
assert use_tables is False
|
|
assert parameters.temperature_degC == pytest.approx(10.0)
|