* fix(optimization): let the AC setpoint cap the total charge where the inverter does Some hybrid inverters limit the battery's whole charge current to the grid charge setpoint while grid charging is on. A Deye 12K in time-of-use grid charging with max_grid_charge_current = 75 A charges at ~80 A even with 8 kW of PV, and exports the rest - including the surplus of micro inverters on the grid side. GENETIC modelled an AC slot as "PV surplus first, grid adds ac_charge x the remaining charge power", so under PV surplus an AC slot looked at least as good as a DC slot and the optimizer picked a low AC factor, while the real system exported what the plan meant to store. New inverter config option devices.inverters[].ac_charge_limits_total_charge (GENETIC scope, default False, so the existing model is unchanged). When True, an AC slot caps the battery's raw charge at ac_charge x max_charge_power_w from all sources: PV surplus above the cap is exported, the grid only fills what PV leaves of it. The option reaches the optimizer through InverterCommonSettings.to_genetic_param, i.e. POST /v1/optimize and the EMS run. GENETIC0 (POST /optimize) is left as it is. The AC slot logic moves into Inverter (ac_charge_factor, begin_ac_charge_slot, charge_battery_from_grid) so the simulation and the tail value curve share it; Battery gets a per-slot charge cap that reset() lifts again. * test(optimization): narrow optional simulation arrays for mypy The annotated fixture indexes GeneticSimulation arrays typed as Optional; assert them first so the locked mypy hook passes.