% SPDX-License-Identifier: Apache-2.0
|
|
(measurement-page)=
|
|
|
|
# Measurements
|
|
|
|
Measurements are utilized to refine predictions using real data from your system, thereby enhancing
|
|
accuracy.
|
|
|
|
- Household Load Measurement
|
|
- Grid Export Measurement
|
|
- Grid Import Measurement
|
|
|
|
## Storing Measurements
|
|
|
|
EOS stores measurements in a **key-value store**, where the term `measurement key` refers to the
|
|
unique identifier used to store and retrieve specific measurement data.
|
|
|
|
Several endpoints of the EOS REST server allow for the management and retrieval of these
|
|
measurements.
|
|
|
|
The measurement data must be or is provided in one of the following formats:
|
|
|
|
### 1. DateTimeData
|
|
|
|
A dictionary with the following structure:
|
|
|
|
```json
|
|
{
|
|
"start_datetime": "2024-01-01 00:00:00",
|
|
"interval": "1 hour",
|
|
"<measurement key>": [value, value, ...],
|
|
"<measurement key>": [value, value, ...],
|
|
...
|
|
}
|
|
```
|
|
|
|
### 2. DateTimeDataFrame
|
|
|
|
A JSON string created from a [pandas](https://pandas.pydata.org/docs/index.html) dataframe with a
|
|
`DatetimeIndex`. Use [pandas.DataFrame.to_json(orient="index")](https://pandas.pydata.org/docs/reference/api/pandas.DataFrame.to_json.html#pandas.DataFrame.to_json).
|
|
The column name of the data must be the same as the names of the `measurement key`s.
|
|
|
|
### 3. DateTimeSeries
|
|
|
|
A JSON string created from a [pandas](https://pandas.pydata.org/docs/index.html) series with a
|
|
`DatetimeIndex`. Use [pandas.Series.to_json(orient="index")](https://pandas.pydata.org/docs/reference/api/pandas.Series.to_json.html#pandas.Series.to_json).
|
|
|
|
Creates a dictionary like this:
|
|
|
|
```json
|
|
{
|
|
"data": {
|
|
"2024-01-01T00:00:00+01:00": 1,
|
|
"2024-01-02T00:00:00+01:00": 2,
|
|
"2024-01-03T00:00:00+01:00": 3,
|
|
...
|
|
},
|
|
"dtype": "float64",
|
|
"tz": "Europe/Berlin"
|
|
}
|
|
```
|
|
|
|
## Load Measurement
|
|
|
|
The EOS measurement store provides for storing energy meter readings of loads.
|
|
|
|
The associated `measurement key`s can be configured by:
|
|
|
|
```json
|
|
{
|
|
"measurement": {
|
|
"load_emr_keys": ["load0_emr", "my special load", ...]
|
|
}
|
|
}
|
|
```
|
|
|
|
Load measurements can be stored for any datetime. The values between different meter readings are
|
|
linearly approximated. Storing values between optimization intervals is generally not useful.
|
|
|
|
The EOS measurement store automatically sums all given loads to create a total load value series
|
|
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
|
|
An interval that the meters do not fully cover (before the first or after the last reading, a meter
|
|
reset, or a gap longer than the meter's gap limit) has no value instead of zero load; with
|
|
several load meters, all of them must cover it. The `LoadAkkudoktorAdjusted` provider skips hours
|
|
without a value.
|
|
|
|
### Meter gaps
|
|
|
|
The energy between two readings of a `*_emr_keys` meter (load, grid import/export, PV production)
|
|
is spread evenly over the time between them. A gap longer than `measurement.emr_max_gap_seconds`
|
|
(default 10800 s, 3 hours) has no energy value instead: an outage of EOS or of the meter does not
|
|
turn into invented, even consumption or production, nights included.
|
|
|
|
```json
|
|
{
|
|
"measurement": {
|
|
"emr_max_gap_seconds": 10800
|
|
}
|
|
}
|
|
```
|
|
|
|
Set it to `null` to spread every gap evenly (the behaviour before the limit). A feeder that only
|
|
sends a reading when the meter value changes (e.g. a PV or export meter that stands still at night)
|
|
needs `null` or a value longer than its longest still period; the Home Assistant adapter reads
|
|
the meters on every energy management run and needs no change.
|
|
|
|
A single meter can get its own limit with a `channels` entry, which takes precedence:
|
|
|
|
```json
|
|
{
|
|
"measurement": {
|
|
"pv_production_emr_keys": ["pv1_emr"],
|
|
"channels": {
|
|
"pv1_emr": {
|
|
"quantity": "cumulative_energy",
|
|
"unit": "kWh",
|
|
"max_gap_seconds": 43200
|
|
}
|
|
}
|
|
}
|
|
}
|
|
```
|
|
|
|
The entry of a `*_emr_keys` meter must stay `cumulative_energy` in `kWh`.
|
|
|
|
:::{admonition} Warning
|
|
:class: warning
|
|
Only use **actual meter readings** in **kWh**, not energy consumption.
|
|
Example: `112345.77`, `112389.23`, `112412.55`, …
|
|
:::
|
|
|
|
## Grid Export/ Import Measurement
|
|
|
|
The EOS measurement store also allows for the storage of meter readings for grid import and export.
|
|
|
|
The associated `measurement key`s can be configured by:
|
|
|
|
```json
|
|
{
|
|
"measurement": {
|
|
"grid_export_emr_keys": ["grid_export_emr", ...],
|
|
"grid_import_emr_keys": ["grid_import_emr", ...],
|
|
}
|
|
}
|
|
```
|
|
|
|
:::{admonition} Todo
|
|
:class: note
|
|
Currently not used. Integrate grid meter readings into the respective predictions.
|
|
:::
|
|
|
|
## Battery/ Electric Vehicle State of Charge (SoC) Measurement
|
|
|
|
The state of charge (SoC) measurement of batteries and electric vehicle batteries can be stored.
|
|
|
|
The associated `measurement key` is pre-defined by the device configuration. It can be
|
|
determined from the device configuration by the read-only `measurement_key_soc_factor` configuration
|
|
option.
|
|
|
|
## Battery/ Electric Vehicle Power Measurement
|
|
|
|
The charge/ discharge power measurements of batteries and electric vehicle batteries can be stored.
|
|
Charging power is denoted by a negative value, discharging power by a positive value.
|
|
|
|
The associated `measurement key`s are pre-defined by the device configuration. They can be
|
|
determined from the device configuration by read-only configuration options:
|
|
|
|
- `measurement_key_power_l1_w`
|
|
- `measurement_key_power_l2_w`
|
|
- `measurement_key_power_l3_w`
|
|
- `measurement_key_power_3_phase_sym_w`
|