A battery profile describes a battery model: the charge and discharge limit
maps over temperature and SoC, the charge and discharge efficiency curves
over C-rate, the technical SoC bounds, the hard temperature cutoffs and,
for a model, its nominal capacity and power limits. EOS packages the
generic profile generic-lfp; users add their own profiles.
A battery or electric vehicle selects its profile by battery_profile and
describes how the installation differs from it in profile_adjustment
(capacity, power limits of the installation, periodic full charge). The
effective values are resolved from both at the measured operating point
(temperature, SoC, power) and shown as effective_* fields.
The GENETIC simulation uses the limits and efficiencies of the profile over
SoC, with precomputed tables as a fast path; GENETIC0 gets the values at the
operating point. Optimization parameters are always valid: a battery whose
profile is missing, unreadable or invalid uses the packaged generic-lfp
profile, and the former defaults only if that is not usable either; each is
logged as error, and an optimization run is never cancelled because of a
battery.
Additional changes
- Add a generic device profile store: user and packaged profiles, atomic
saves, compiled profiles cached per file and checked again at most once a
second, plain file names as profile names ('schema' is reserved). On
Windows, a save or read that collides with the other is retried briefly.
- Add the REST API /v1/profile to list the profile kinds and to list, read
(document and JSON schema), save and delete profiles.
- Check the hard temperature cutoffs on the exact temperature.
- Resolve inhibited charging or discharging to a power of 0, e.g. for a cold
battery; give GENETIC0 its own discharge limit for that.
- Limit generic profiles without own power limits to the former 5000 W.
- Accept only the implemented units; current limits need the nominal
voltage.
- Migrate legacy battery settings into the profile adjustment, keep the
former charge power limit as discharge limit (also for a Home Assistant
entity on it) and report dropped efficiencies as errors.
- Limit GENETIC battery discharge by the discharge power.
- Allow battery profile lookups while the configuration is created.
- Resolve a battery once per configuration dump.
- Package the bundled profiles, document battery profiles and regenerate
the configuration and OpenAPI documentation.
- Ignore the report PDFs written by the visualization tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
479 lines
22 KiB
Markdown
479 lines
22 KiB
Markdown
% SPDX-License-Identifier: Apache-2.0
|
||
(resource-page)=
|
||
|
||
# Resources (Device Simulations)
|
||
|
||
## Concepts
|
||
|
||
The simulations for resources are leaning on general concepts of the [S2 standard].
|
||
|
||
### Control Types
|
||
|
||
The control of resources and such what a resource simulation will simulate follows three
|
||
basic control principles:
|
||
|
||
- Operation Mode Based Control (OMBC)
|
||
- Fill Rate Based Control (FRBC)
|
||
- Demand Driven Based Control (DDBC)
|
||
|
||
Although these control principles differ enough to separate them into three distinct control types,
|
||
there are some common aspects that make them similar:
|
||
|
||
- Operation Modes
|
||
- Transitions and
|
||
- Timers.
|
||
|
||
The objective for a control type is under which circumstances what things can be adjusted, and what
|
||
the constraints are for these adjustments. The three control types model a virtual, abstract resource
|
||
for simulation.
|
||
|
||
The abstract resource ignores all details of pyhsical device that are not relevant to energy
|
||
management. In addition, physical devices have an enormous variety in parameters, sensors, control
|
||
strategies, concerns, safeguards, and so on. It would be practically impossible to develop a
|
||
simulation that can
|
||
understand all the parameters of all the physical devices on the market. By making the resource more
|
||
abstract, its concepts can be translated to all sorts of physical devices, even though internally
|
||
they function very differently. As a consequence, it not always possible to make a 100% accurate
|
||
description of all the behaviors and constraints in these abstractions. But the abstractions used
|
||
in the control types are quite powerful, and should allow you to come pretty close.
|
||
|
||
The control types basically define how the simulated resource can be described. The user in the end
|
||
selects the proper desciption of a physical device using the configuration options provided for
|
||
resource simulations. The configuration sets how the simulated resource functions, what it can do and
|
||
what kind of constraints it has.
|
||
|
||
### Resource Simulation
|
||
|
||
Based on the description of this virtual resource, the resource simulation can make predictions of
|
||
what the physical device will do in certain situations, and when it is allowed to execute
|
||
instructions generated by the optimization as part of the energy management plan evaluation.
|
||
|
||
### Resource Status
|
||
|
||
Once the physical device has changed it's behavior, the resource simulation should be informed
|
||
to make the simulation change it's state accordingly.
|
||
|
||
The actual state of a pyhsical device may be reported to the resource simulation by the
|
||
**PUT** `/v1/resource/status` API endpoint.
|
||
|
||
## Battery
|
||
|
||
There is a wealth of possible battery operation modes:
|
||
|
||
<!-- pyml disable line-length -->
|
||
| Mode | Purpose / Behavior | Typical Trigger / Context |
|
||
| ------------------------- | --------------------------------------------------------------------------------------- | ---------------------------------------------------------------- |
|
||
| **IDLE** | Battery neither charges nor discharges (SOC stable). | No active control objective or power imbalance below thresholds. |
|
||
| **SELF_CONSUMPTION** | Charge from PV surplus and discharge to cover local load. | PV generation > load (charge) or load > PV (discharge). |
|
||
| **NON_EXPORT** | Charge from on-site or local surplus with the goal of minimizing or preventing energy export to the external grid. Discharging to the grid is not allowed. | Export limit reached and SOC < SOC_max. |
|
||
| **PEAK_SHAVING** | Discharge to keep grid import below a target threshold. | Predicted or measured site load exceeds peak limit. |
|
||
| **GRID_SUPPORT_EXPORT** | Discharge energy to grid for revenue (V2G, wholesale market, flexibility service). | Market or signal permits profitable export. |
|
||
| **GRID_SUPPORT_IMPORT** | Charge from grid to absorb surplus or provide up-regulation service. | Low-price or grid-support signal detected. |
|
||
| **FREQUENCY_REGULATION** | Rapid charge/discharge response to grid frequency deviations. | Active participation in frequency control. |
|
||
| **RAMP_RATE_CONTROL** | Smooth site-level power ramp rates by buffering fluctuations. | Sudden PV/load change exceeding ramp limit. |
|
||
| **RESERVE_BACKUP** | Maintain SOC ≥ reserve threshold to ensure backup capacity. | Resilience mode active, grid operational. |
|
||
| **OUTAGE_SUPPLY** | Islanded operation: power local loads using stored energy (and PV if available). | Grid failure detected. |
|
||
| **FORCED_CHARGE** | Manual or external control command to charge (e.g., pre-event, maintenance). No discharge. | Operator or optimizer command. |
|
||
| **FORCED_DISCHARGE** | Manual or external control command to discharge. No charge. | Operator or optimizer command. |
|
||
| **FAULT** | Battery unavailable due to fault, safety, or protection state. | Fault detected (thermal, voltage, comms, etc.). |
|
||
<!-- pyml enable line-length -->
|
||
|
||
The optimization algorithm, the device simulation and the configuration properties only support the
|
||
most important of these modes.
|
||
|
||
### Battery Simulation
|
||
|
||
The battery simulation assumes an idealized battery model. Under this model, the battery can be
|
||
operated in three discrete operation modes with fill rate based control (FRBC):
|
||
|
||
| **Operation Mode ID** | **Description** |
|
||
| ------------------------ | --------------------------------------------------------------------- |
|
||
| **SELF_CONSUMPTION** | Charge from local surplus and discharge to cover local load. |
|
||
| **NON_EXPORT** | Charge from local surplus and do not discharge. |
|
||
| **FORCED_CHARGE** | Charge. |
|
||
|
||
The **operation mode factor** (0.0–1.0) specifies the normalized power rate relative to the
|
||
battery's nominal maximum charge or discharge power. A value of 1.0 corresponds to full-rate
|
||
charging or discharging, while 0.0 indicates no power transfer. Intermediate values scale the power
|
||
proportionally.
|
||
|
||
The **fill level** (0.0–1.0) specifies the normalized fill level relative to the
|
||
battery's nominal maximum charge. A value of 1.0 corresponds to full while 0.0 indicates empty.
|
||
Intermediate values scale the fill level proportionally.
|
||
|
||
### Battery Configuration
|
||
|
||
The technical data of a battery or electric vehicle comes from a **battery profile**. The
|
||
configuration of the device (`devices/batteries/<device_id>` or
|
||
`devices/electric_vehicles/<device_id>`) selects the profile, adjusts it to the installed unit and
|
||
sets how the battery is operated:
|
||
|
||
| **Field** | **Description** |
|
||
| -------------------------------------------------- | --------------------------------------------------------------- |
|
||
| `battery_profile` | Battery profile name (without `.json`), default `generic-lfp`. |
|
||
| `profile_adjustment/nominal_capacity_wh` | Capacity of the installed unit [Wh]. Replaces the profile's. |
|
||
| `profile_adjustment/max_charge_power_w` | Charge power limit of the installation [W]. Only lowers. |
|
||
| `profile_adjustment/max_discharge_power_w` | Discharge power limit of the installation [W]. Only lowers. |
|
||
| `profile_adjustment/full_charge_interval_days` | Days between two full charges [d]. Replaces the profile's. |
|
||
| `profile_adjustment/full_charge_detect_percentage` | SoC that counts as full [%]. Replaces the profile's. |
|
||
| `min_soc_percentage` | Minimum SoC [%], at least the technical minimum of the profile. |
|
||
| `max_soc_percentage` | Maximum SoC [%], at most the technical maximum of the profile. |
|
||
|
||
```json
|
||
"house": {
|
||
"battery_profile": "generic-lfp",
|
||
"profile_adjustment": {
|
||
"nominal_capacity_wh": 10240,
|
||
"max_charge_power_w": 5000,
|
||
"max_discharge_power_w": 5000
|
||
},
|
||
"min_soc_percentage": 10,
|
||
"max_soc_percentage": 95
|
||
}
|
||
```
|
||
|
||
EOS resolves every effective parameter from exactly two sources, the profile and the profile
|
||
adjustment, evaluated at the operating point (battery temperature and SoC). There are no built-in
|
||
fallback values:
|
||
|
||
- **Capacity**: `profile_adjustment/nominal_capacity_wh`, else the nominal capacity of the
|
||
profile. A generic profile such as `generic-lfp` describes its limits as C-rates and has no
|
||
capacity of its own, so the adjustment has to provide it.
|
||
- **Power limits**: the profile limit maps give the maximum charge and discharge rate per
|
||
temperature and SoC. The power limits of the adjustment can only lower them. At temperatures
|
||
outside the hard cutoffs of the profile charging or discharging is inhibited.
|
||
- **Efficiencies**: the profile efficiency curves at the charge and discharge power.
|
||
|
||
The GENETIC optimization evaluates the profile at the measured battery temperature, or at 25 °C if
|
||
no temperature is measured. Its battery simulation then limits the charge and discharge power
|
||
by the SoC at the start of each charge or discharge step, and takes the charge and discharge
|
||
efficiency at the power of the slot.
|
||
|
||
The resolved values are shown as read-only fields of the device configuration
|
||
(`effective_nominal_capacity_wh`, `effective_max_charge_power_w`, `effective_max_discharge_power_w`,
|
||
`effective_charging_efficiency`, `effective_discharging_efficiency`, `effective_min_soc_percentage`,
|
||
`effective_max_soc_percentage`, `effective_full_charge_interval_days`,
|
||
`effective_full_charge_detect_percentage`). These fields are evaluated at the reference operating point of
|
||
25 °C and 50 % SoC.
|
||
|
||
If a battery cannot be resolved, e.g. its profile does not exist or a generic profile lacks the
|
||
capacity in the adjustment, its read-only fields are empty (`null`) and EOS logs an error naming
|
||
the battery whenever the configuration is set up or changed. A power limit in the adjustment above
|
||
the profile limit has no effect and is logged as a warning.
|
||
|
||
The parameter preparation of the GENETIC and GENETIC0 optimizations always succeeds for such a
|
||
configuration error. It resolves whatever the configuration allows and fills only the rest with
|
||
the defaults of earlier versions, and it logs an error that names the battery, the problem and the
|
||
default values used:
|
||
|
||
- **Profile not usable** (missing, unreadable, invalid): the packaged generic profile
|
||
`generic-lfp` with the profile adjustment.
|
||
- **Generic profile not usable either**: the profile adjustment where set, else 8000 Wh, 5000 W
|
||
charge and discharge power and efficiencies of 0.88, without SoC dependent power limits.
|
||
- **Generic profile without capacity in the adjustment**: the profile with a capacity of 8000 Wh.
|
||
- **SoC range outside the technical SoC bounds of the profile**: the technical SoC range.
|
||
|
||
A profile that inhibits charging at the measured battery temperature is not a configuration
|
||
error; the optimization reports it as error.
|
||
|
||
:::{admonition} Note
|
||
:class: note
|
||
Configurations of earlier versions are migrated automatically. `capacity_wh` becomes
|
||
`profile_adjustment/nominal_capacity_wh` and `max_charge_power_w` becomes the installation limit
|
||
`profile_adjustment/max_charge_power_w`. A battery that relied on the former defaults gets them
|
||
written into its profile adjustment (8000 Wh, 5000 W), so its capacity and charge limit do not
|
||
change. The former fields `charging_efficiency` and `discharging_efficiency` are computed from the
|
||
profile now and are dropped. The periodic full charge settings `full_charge_interval_days` and
|
||
`full_charge_detect_percentage` move into the profile adjustment, `cell_chemistry` is dropped (the
|
||
profile has the `chemistry`). Home Assistant `config_entity_ids` that point at moved fields are
|
||
rewritten to the new paths. An entity on the former `max_charge_power_w` sets both
|
||
`profile_adjustment/max_charge_power_w` and `profile_adjustment/max_discharge_power_w`, unless the
|
||
discharge limit has its own entity.
|
||
:::
|
||
|
||
#### Battery Profiles
|
||
|
||
A battery profile is a JSON document with:
|
||
|
||
- charge and discharge limit maps over temperature and SoC (as C-rate, W or A), with their axes
|
||
and units,
|
||
- charge and discharge efficiency curves over the C-rate,
|
||
- technical SoC bounds and hard temperature cutoffs for charging and discharging,
|
||
- the nominal capacity, except for a generic profile,
|
||
- optionally the nominal voltage and model power limits,
|
||
- optionally the cell chemistry and the periodic full charge the battery management system needs
|
||
to recalibrate its SoC: `full_charge_interval_days` (none by default) and
|
||
`full_charge_detect_percentage` (default 99), see the periodic full charge of the GENETIC
|
||
optimization.
|
||
|
||
All of these are required, except the optional ones. Unknown keys are rejected, so a misspelled
|
||
key fails validation instead of being ignored.
|
||
|
||
EOS ships the profile `generic-lfp` for a generic LFP home battery. Profiles are looked up by name
|
||
first in the user data directory `<general/data_folder_path>/profile/battery/` and then in the
|
||
packaged profiles. Saving a profile always writes to the user data directory; a user profile with
|
||
the name of a packaged profile replaces it until the user profile is deleted. Changed profiles are
|
||
used on their next access, without a restart of EOS. A profile name is the file name without
|
||
`.json`: letters, digits, `.`, `_` and `-`, starting with a letter or digit, at most 100
|
||
characters. `schema` is reserved.
|
||
|
||
Profiles can be managed with the REST API:
|
||
|
||
| **Endpoint** | **Description** |
|
||
| -------------------------------------- | ---------------------------------------------------------------- |
|
||
| **GET** `/v1/profile` | List the profile kinds (e.g. `battery`). |
|
||
| **GET** `/v1/profile/{kind}` | List the user and packaged profiles of a kind. |
|
||
| **GET** `/v1/profile/{kind}/schema` | JSON schema of the profile documents of a kind. |
|
||
| **GET** `/v1/profile/{kind}/{name}` | Get a profile document. |
|
||
| **PUT** `/v1/profile/{kind}/{name}` | Validate a profile document and save it as user profile. |
|
||
| **DELETE** `/v1/profile/{kind}/{name}` | Delete a user profile. Returns the profile that applies instead. |
|
||
|
||
The **Profiles** page of EOSdash edits battery profiles as JSON and plots the limit maps and
|
||
efficiency curves as EOS evaluates them. Edits can be previewed before they are saved.
|
||
|
||
To share a profile with other users, open it on the **Profiles** page and press **Share on
|
||
GitHub**. It opens a new issue with the battery profile form in your browser, filled in with the
|
||
profile; check it and submit it. EOS sends nothing itself. Reviewed profiles are packaged with
|
||
EOS.
|
||
|
||
### Battery Stati
|
||
|
||
To keep the battery simulation in synchonization with the actual stati of the battery the following
|
||
resource stati may be reported to EOS by the **PUT** `/v1/resource/status` API endpoint.
|
||
|
||
#### Battery FRBCActuatorStatus
|
||
|
||
The operation mode the battery is currently operated.
|
||
|
||
```json
|
||
{
|
||
"type": "FRBCActuatorStatus",
|
||
"active_operation_mode_id": "GRID_SUPPORT_IMPORT",
|
||
"operation_mode_factor": "0.375",
|
||
"previous_operation_mode_id": "SELF_CONSUMPTION",
|
||
"transistion_timestamp": "20250725T12:00:12"
|
||
}
|
||
```
|
||
|
||
#### Battery FRBCStorageStatus
|
||
|
||
The current battery state of charge (SoC).
|
||
|
||
```json
|
||
{
|
||
"type": "FRBCStorageStatus",
|
||
"present_fill_level": "0.88"
|
||
}
|
||
```
|
||
|
||
#### Battery PowerMeasurement
|
||
|
||
The current power that the battery is charged or discharged with \[W\].
|
||
|
||
```json
|
||
{
|
||
"type": "PowerMeasurement",
|
||
"measurement_timestamp": "20250725T12:00:12",
|
||
"values": [
|
||
{
|
||
"commodity_quantity": "ELECTRIC.POWER.L1",
|
||
"value": "887.5"
|
||
},
|
||
{
|
||
"commodity_quantity": "ELECTRIC.POWER.L2",
|
||
"value": "905.5"
|
||
},
|
||
{
|
||
"commodity_quantity": "ELECTRIC.POWER.L2",
|
||
"value": "1100.7"
|
||
},
|
||
]
|
||
}
|
||
```
|
||
|
||
For symmetric (or unknown) power distribution:
|
||
|
||
```json
|
||
{
|
||
"type": "PowerMeasurement",
|
||
"measurement_timestamp": "20250725T12:00:12",
|
||
"values": [
|
||
{
|
||
"commodity_quantity": "ELECTRIC.POWER.3_PHASE_SYM",
|
||
"value": "1000"
|
||
}
|
||
]
|
||
}
|
||
```
|
||
|
||
## Electric Vehicle
|
||
|
||
The electric vehicle is basically a battery with a reduced set of operation modes.
|
||
|
||
### Electric Vehicle Instructions
|
||
|
||
The electric vehicle control instructions assume an idealized EV battery model. Under this model,
|
||
the EV battery can be operated in two operation modes:
|
||
|
||
| **Operation Mode ID** | **Description** |
|
||
| --------------------- | ----------------------------------------------------------------------- |
|
||
| **IDLE** | Battery neither charges nor discharges; holds its state of charge. |
|
||
| **FORCED_CHARGE** | Charge at a specified power rate up to the allowable maximum. |
|
||
|
||
The **operation mode factor** (0.0–1.0) specifies the normalized power rate relative to the
|
||
battery's nominal maximum charge power. A value of 1.0 corresponds to full-rate charging, while 0.0
|
||
indicates no power transfer. Intermediate values scale the power proportionally.
|
||
|
||
## Home Appliance
|
||
|
||
The optimization algorithm supports one start of the home appliance within the optimization
|
||
horizon.
|
||
|
||
### Home Appliance Simulation
|
||
|
||
### GENETIC0 Home Appliance Configuration
|
||
|
||
Home appliance to run within the optimization horizon.
|
||
|
||
```json
|
||
{
|
||
"dishwasher1": {
|
||
"device_id": "dishwasher1",
|
||
"consumption_wh": 2000,
|
||
"duration_h": 3
|
||
}
|
||
}
|
||
```
|
||
|
||
Home appliance to run within a time window of 5 hours starting at 8:00 every day and another time
|
||
window of 3 hours starting at 15:00 every day. See
|
||
[Time Window Sequence Configuration](configtimewindow-page) for more information.
|
||
|
||
```json
|
||
{
|
||
"dishwasher1": {
|
||
"device_id": "dishwasher1",
|
||
"consumption_wh": 2000,
|
||
"duration_h": 3,
|
||
"time_windows": {
|
||
"windows": [
|
||
{
|
||
"start_time": "08:00",
|
||
"duration": "5 hours"
|
||
},
|
||
{
|
||
"start_time": "15:00",
|
||
"duration": "3 hours"
|
||
}
|
||
]
|
||
}
|
||
}
|
||
}
|
||
```
|
||
|
||
:::{admonition} Note
|
||
:class: note
|
||
The optimization algorithm always restricts to one start within the optimization horizon per
|
||
energy management run.
|
||
:::
|
||
|
||
### GENETIC Home Appliance Configuration
|
||
|
||
Home appliance to run once, unconstrained, within the optimization horizon:
|
||
|
||
```json
|
||
{
|
||
"dishwasher1": {
|
||
"device_id": "dishwasher1",
|
||
"consumption_wh": 2000,
|
||
"duration_h": 3,
|
||
"num_cycles": 1
|
||
}
|
||
}
|
||
```
|
||
|
||
Home appliance to run within a time window of 5 hours starting at 8:00. Each window's `value`
|
||
field carries the 0-based cycle index it applies to -- here there is only one cycle (index `0`),
|
||
so `num_cycles` does not need to be set explicitly; it is derived from the distinct cycle indices
|
||
found in `cycle_time_windows`. See
|
||
[ime Window Sequence Configuration](configimewindow-page) for more information.
|
||
|
||
```json
|
||
{
|
||
"dishwasher1": {
|
||
"device_id": "dishwasher1",
|
||
"consumption_wh": 2000,
|
||
"duration_h": 3,
|
||
"cycle_time_windows": {
|
||
"windows": [
|
||
{
|
||
"start_time": "08:00",
|
||
"duration": "5 hours",
|
||
"value": 0
|
||
}
|
||
]
|
||
}
|
||
}
|
||
}
|
||
```
|
||
|
||
Home appliance that must run **twice** per day, each run confined to its own time window --
|
||
cycle 0 in the morning (07:00, 5 hours), cycle 1 in the evening (17:00, 5 hours) -- with at least
|
||
1 hour idle between the two runs:
|
||
|
||
```json
|
||
{
|
||
"washing_machine1": {
|
||
"device_id": "washing_machine1",
|
||
"consumption_wh": 2000,
|
||
"duration_h": 2,
|
||
"min_cycle_gap_h": 1,
|
||
"cycle_time_windows": {
|
||
"windows": [
|
||
{
|
||
"start_time": "07:00",
|
||
"duration": "5 hours",
|
||
"value": 0
|
||
},
|
||
{
|
||
"start_time": "17:00",
|
||
"duration": "5 hours",
|
||
"value": 1
|
||
}
|
||
]
|
||
}
|
||
}
|
||
}
|
||
```
|
||
|
||
`min_cycle_gap_h` enforces a minimum idle time between the end of one cycle and the start of the
|
||
next; it defaults to `0`, which permits back-to-back runs. To let both cycles run anywhere in a
|
||
shared window instead of separate morning/evening slots, give both windows the same `start_time`
|
||
and `duration` but keep their distinct `value` (cycle index) -- the optimizer still places each
|
||
cycle independently within that shared window.
|
||
|
||
How many cycles remain to be scheduled on a given energy management run is read at runtime from
|
||
the measurement store, under the key configured in `cycles_completed_measurement_key` (defaults
|
||
to `{device_id}.cycles_completed`). This lets the optimizer skip cycles the appliance has already
|
||
completed earlier the same day.
|
||
|
||
:::{admonition} Note
|
||
:class: note
|
||
Unlike GENETIC0, the GENETIC algorithm can plan multiple cycles -- and therefore multiple starts
|
||
-- of the same appliance within a single energy management run, whenever `num_cycles` (or the
|
||
number of distinct cycle indices in `cycle_time_windows`) is greater than 1.
|
||
:::
|
||
|
||
### Home Appliance Instructions
|
||
|
||
The home appliance instructions assume an idealized home appliance model. Under this model,
|
||
the home appliance can be operated in two operation modes:
|
||
|
||
| **Operation Mode ID** | **Description** |
|
||
|-----------------------|-------------------------------------------------------------------------|
|
||
| **RUN** | The home appliance is started and runs until the end of it's power |
|
||
| | sequence. |
|
||
| **OFF** | The home appliance does not run. |
|
||
|
||
The **operation mode factor** (0.0–1.0) is ignored.
|