FAstAPI is an async framework. Data may be imported and exported, load and save, set and get asynchronously. Prevent interleaving data operations to corrupt the data. In the previous design sync and async data access was intermixed leading to data corruption. The basic data classes DataSequence and DataContainer and the derived classes like Provider and Measurement now are async. Data access is protected by several async locks. To support the async design of the data classes the database interface became async. The energy management is also adapted to the new async design. Optimization is still off-loaded to another thread, but the prepration for the optimization and the post optimization actions now follow the async design. Adapter operations are now also protected by async locks. Tests were adapted to the async design and new tests were created. Besides this major fix several other improvements and fixes are included in this PR. * fix: key_to_dict/list/array only regard data records with key value set. Before the exclusion of no value data records was only done if the dropna flag was set. * fix: test for visual result pdf generation Due to updates in the library the generated charts text was a little bit different. Adapt the test to create the comaprison pdf in the test data durectory and update the reference pdf. * chore: Remove MutableMapping from DataSequence and DataContainer. Mutable Mapping does not fit to the now async design. * chore: Add NoDB database backend This backend implements the full database backend interface but performs no actual persistence. It is intended for configurations where database persistence is disabled (`provider=None`). * chore: Improve measurement data import testing with real world scenarios. Added two new endpoints to support testing. * chore: Add mermaid to supported documentation tools * chore: Add documentation about async design * chore: Add documentation about generic data handling Covers the basics of measurement and prediction time series data handling. * chore: Add empty lines around markdown lists. * chore: sync pre-commit config to updated package versions Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
21 KiB
Base configuration for devices simulation settings
:::{table} devices :widths: 10 20 10 5 5 30 :align: left
| Name | Environment Variable | Type | Read-Only | Default | Description |
|---|---|---|---|---|---|
| batteries | EOS_DEVICES__BATTERIES |
Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]] |
rw |
None |
List of battery devices |
| electric_vehicles | EOS_DEVICES__ELECTRIC_VEHICLES |
Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]] |
rw |
None |
List of electric vehicle devices |
| home_appliances | EOS_DEVICES__HOME_APPLIANCES |
Optional[list[akkudoktoreos.devices.devices.HomeApplianceCommonSettings]] |
rw |
None |
List of home appliances |
| inverters | EOS_DEVICES__INVERTERS |
Optional[list[akkudoktoreos.devices.devices.InverterCommonSettings]] |
rw |
None |
List of inverters |
| max_batteries | EOS_DEVICES__MAX_BATTERIES |
Optional[int] |
rw |
None |
Maximum number of batteries that can be set |
| max_electric_vehicles | EOS_DEVICES__MAX_ELECTRIC_VEHICLES |
Optional[int] |
rw |
None |
Maximum number of electric vehicles that can be set |
| max_home_appliances | EOS_DEVICES__MAX_HOME_APPLIANCES |
Optional[int] |
rw |
None |
Maximum number of home_appliances that can be set |
| max_inverters | EOS_DEVICES__MAX_INVERTERS |
Optional[int] |
rw |
None |
Maximum number of inverters that can be set |
| measurement_keys | Optional[list[str]] |
ro |
N/A |
Return the measurement keys for the resource/ device stati that are measurements. | |
| ::: |
Example Input
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100
}
],
"max_batteries": 1,
"electric_vehicles": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100
}
],
"max_electric_vehicles": 1,
"inverters": [],
"max_inverters": 1,
"home_appliances": [],
"max_home_appliances": 1
}
}
Example Output
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
],
"max_batteries": 1,
"electric_vehicles": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
],
"max_electric_vehicles": 1,
"inverters": [],
"max_inverters": 1,
"home_appliances": [],
"max_home_appliances": 1,
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w",
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
}
Inverter devices base settings
:::{table} devices::inverters::list :widths: 10 10 5 5 30 :align: left
| Name | Type | Read-Only | Default | Description |
|---|---|---|---|---|
| ac_to_dc_efficiency | float |
rw |
1.0 |
Efficiency of AC to DC conversion for grid-to-battery AC charging (0-1). Set to 0 to disable AC charging. Default 1.0 (no additional inverter loss). |
| battery_id | Optional[str] |
rw |
None |
ID of battery controlled by this inverter. |
| dc_to_ac_efficiency | float |
rw |
1.0 |
Efficiency of DC to AC conversion for battery discharging to AC load/grid (0-1). Default 1.0 (no additional inverter loss). |
| device_id | str |
rw |
<unknown> |
ID of device |
| max_ac_charge_power_w | Optional[float] |
rw |
None |
Maximum AC charging power in watts. null means no additional limit. Set to 0 to disable AC charging. |
| max_power_w | Optional[float] |
rw |
None |
Maximum power [W]. |
| measurement_keys | Optional[list[str]] |
ro |
N/A |
Measurement keys for the inverter stati that are measurements. |
| ::: |
Example Input
{
"devices": {
"inverters": [
{
"device_id": "battery1",
"max_power_w": 10000.0,
"battery_id": null,
"ac_to_dc_efficiency": 0.95,
"dc_to_ac_efficiency": 0.95,
"max_ac_charge_power_w": null
}
]
}
}
Example Output
{
"devices": {
"inverters": [
{
"device_id": "battery1",
"max_power_w": 10000.0,
"battery_id": null,
"ac_to_dc_efficiency": 0.95,
"dc_to_ac_efficiency": 0.95,
"max_ac_charge_power_w": null,
"measurement_keys": []
}
]
}
}
Model defining a daily or date time window with optional localization support
Represents a time interval starting at start_time and lasting for duration.
Can restrict applicability to a specific day of the week or a specific calendar date.
Supports day names in multiple languages via locale-aware parsing.
Timezone contract:
start_time is always naive (no tzinfo). It is interpreted as a
local wall-clock time in whatever timezone the caller's date_time or
reference_date carries. When those arguments are timezone-aware the
window boundaries are evaluated in that timezone; when they are naive,
arithmetic is performed as-is (no timezone conversion occurs).
date, being a calendar Date object, is inherently timezone-free.
This design avoids the ambiguity that arises when a stored start_time
carries its own timezone that differs from the caller's timezone, and keeps
the model serialisable without timezone state.
:::{table} devices::home_appliances::list::time_windows::windows::list :widths: 10 10 5 5 30 :align: left
| Name | Type | Read-Only | Default | Description |
|---|---|---|---|---|
| date | Optional[pydantic_extra_types.pendulum_dt.Date] |
rw |
None |
Optional specific calendar date for the time window. Naive — matched against the local date of the datetime passed to contains(). Overrides day_of_week if set. |
| day_of_week | Union[int, str, NoneType] |
rw |
None |
Optional day of the week restriction. Can be specified as integer (0=Monday to 6=Sunday) or localized weekday name. If None, applies every day unless date is set. |
| duration | Duration |
rw |
required |
Duration of the time window starting from start_time. |
| locale | Optional[str] |
rw |
None |
Locale used to parse weekday names in day_of_week when given as string. If not set, Pendulum's default locale is used. Examples: 'en', 'de', 'fr', etc. |
| start_time | Time |
rw |
required |
Naive start time of the time window (time of day, no timezone). Interpreted in the timezone of the datetime passed to contains() or earliest_start_time(). |
| ::: |
Example Input/Output
{
"devices": {
"home_appliances": [
{
"time_windows": {
"windows": [
{
"start_time": "00:00:00.000000",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
}
}
]
}
}
Model representing a sequence of time windows with collective operations
Manages multiple TimeWindow objects and provides methods to work with them as a cohesive unit for scheduling and availability checking.
:::{table} devices::home_appliances::list::time_windows :widths: 10 10 5 5 30 :align: left
| Name | Type | Read-Only | Default | Description |
|---|---|---|---|---|
| windows | list[akkudoktoreos.config.configabc.TimeWindow] |
rw |
required |
List of TimeWindow objects that make up this sequence. |
| ::: |
Example Input/Output
{
"devices": {
"home_appliances": [
{
"time_windows": {
"windows": []
}
}
]
}
}
Home Appliance devices base settings
:::{table} devices::home_appliances::list :widths: 10 10 5 5 30 :align: left
| Name | Type | Read-Only | Default | Description |
|---|---|---|---|---|
| consumption_wh | int |
rw |
required |
Energy consumption [Wh]. |
| device_id | str |
rw |
<unknown> |
ID of device |
| duration_h | int |
rw |
required |
Usage duration in hours [0 ... 24]. |
| measurement_keys | Optional[list[str]] |
ro |
N/A |
Measurement keys for the home appliance stati that are measurements. |
| time_windows | Optional[akkudoktoreos.config.configabc.TimeWindowSequence] |
rw |
None |
Sequence of allowed time windows. Defaults to optimization general time window. |
| ::: |
Example Input
{
"devices": {
"home_appliances": [
{
"device_id": "battery1",
"consumption_wh": 2000,
"duration_h": 1,
"time_windows": {
"windows": [
{
"start_time": "10:00:00.000000",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
}
}
]
}
}
Example Output
{
"devices": {
"home_appliances": [
{
"device_id": "battery1",
"consumption_wh": 2000,
"duration_h": 1,
"time_windows": {
"windows": [
{
"start_time": "10:00:00.000000",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
},
"measurement_keys": []
}
]
}
}
Battery devices base settings
:::{table} devices::batteries::list :widths: 10 10 5 5 30 :align: left
| Name | Type | Read-Only | Default | Description |
|---|---|---|---|---|
| capacity_wh | int |
rw |
8000 |
Capacity [Wh]. |
| charge_rates | Optional[list[float]] |
rw |
[0.0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0] |
Charge rates as factor of maximum charging power [0.00 ... 1.00]. None triggers fallback to default charge-rates. |
| charging_efficiency | float |
rw |
0.88 |
Charging efficiency [0.01 ... 1.00]. |
| device_id | str |
rw |
<unknown> |
ID of device |
| discharging_efficiency | float |
rw |
0.88 |
Discharge efficiency [0.01 ... 1.00]. |
| levelized_cost_of_storage_kwh | float |
rw |
0.0 |
Levelized cost of storage (LCOS), the average lifetime cost of delivering one kWh [€/kWh]. |
| max_charge_power_w | Optional[float] |
rw |
5000 |
Maximum charging power [W]. |
| max_soc_percentage | int |
rw |
100 |
Maximum state of charge (SOC) as percentage of capacity [%]. |
| measurement_key_power_3_phase_sym_w | str |
ro |
N/A |
Measurement key for the symmetric 3 phase power the battery is charged or discharged with [W]. |
| measurement_key_power_l1_w | str |
ro |
N/A |
Measurement key for the L1 power the battery is charged or discharged with [W]. |
| measurement_key_power_l2_w | str |
ro |
N/A |
Measurement key for the L2 power the battery is charged or discharged with [W]. |
| measurement_key_power_l3_w | str |
ro |
N/A |
Measurement key for the L3 power the battery is charged or discharged with [W]. |
| measurement_key_soc_factor | str |
ro |
N/A |
Measurement key for the battery state of charge (SoC) as factor of total capacity [0.0 ... 1.0]. |
| measurement_keys | Optional[list[str]] |
ro |
N/A |
Measurement keys for the battery stati that are measurements. |
| min_charge_power_w | Optional[float] |
rw |
50 |
Minimum charging power [W]. |
| min_soc_percentage | int |
rw |
0 |
Minimum state of charge (SOC) as percentage of capacity [%]. This is the target SoC for charging |
| ::: |
Example Input
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.12,
"max_charge_power_w": 5000.0,
"min_charge_power_w": 50.0,
"charge_rates": [
0.0,
0.25,
0.5,
0.75,
1.0
],
"min_soc_percentage": 10,
"max_soc_percentage": 100
}
]
}
}
Example Output
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.12,
"max_charge_power_w": 5000.0,
"min_charge_power_w": 50.0,
"charge_rates": [
0.0,
0.25,
0.5,
0.75,
1.0
],
"min_soc_percentage": 10,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
]
}
}