Alex Beal 0908b03491 Fix: Do not misidentify IMU as an RTC on Heltec T1
The T1 has an ICM-42607-P IMU with the same address as a DS3231 RTC.
This completely breaks the clock on the T1. Reading the time results in
a garbage value, causing all sorts of strange issues. The time never
advances, which breaks logging in to repeaters (due to their time-based
replay protection).

This simply disables the probe on the I2C line. The DS3231 doesn't have
a WHO_AM_I register that could be used to prevent misidentifying it, so
this simpler fix is used.
2026-08-25 15:00:45 -06:00
Alex Beal eb97a375d3 Add an instance of ExternalWatchdogManager to Tower V2 2026-07-12 16:17:23 -06:00
Alex Beal 47e1ce5bae Update #defines
External watchdog support was added (but never merged) for MeshTower V1. The update's V2's #defines to follow the conventions set there and piggy back off the support already written for V1.
2026-07-12 15:50:43 -06:00